DFX300 USER MANUAL
Assembly .........................................................................................................................................................................................2
Batteries .......................................................................................................................................................................................... 4
DFX
™ Quick Start ........................................................................................................................................................................ 8Basic Adjustments ....................................................................................................................................................................... 14
1. Target Volume ..................................................................................................................................................................... 18
2. Audio Threshold ................................................................................................................................................................. 18
3. Tone (Audio Frequency) ..................................................................................................................................................... 19
4. Audio Disc. ......................................................................................................................................................................... 19
5. Silent Search ....................................................................................................................................................................... 20
6. Mixed Mode ........................................................................................................................................................................ 21
7. A.C. Sensitivity ................................................................................................................................................................... 22
8. D.C. Sensitivity ................................................................................................................................................................... 22
9. Backlight ............................................................................................................................................................................. 23
10. Viewing Angle .................................................................................................................................................................. 24
Pro Options .................................................................................................................................................................................. 25
Audio
......................................................................................................................................................................................... 271. Ratchet Pinpointing ............................................................................................................................................................ 27
2. S.A.T. Speed ....................................................................................................................................................................... 27
3. Tone I.D. ............................................................................................................................................................................. 28
4. V.C.O. ................................................................................................................................................................................. 28
5. Modulation .......................................................................................................................................................................... 28
G.E.B./Trac
............................................................................................................................................................................ 296. AutoTrac
® ............................................................................................................................................................................ 297. Trac View ............................................................................................................................................................................ 29
8. Trac Speed .......................................................................................................................................................................... 30
9. Trac Offset .......................................................................................................................................................................... 31
10. Trac Inhibit ........................................................................................................................................................................ 31
11. Coarse G.E.B. ................................................................................................................................................................... 32
12. Fine G.E.B. ....................................................................................................................................................................... 33
Discrimination ......................................................................................................................................................................... 34
13. Disc. Edit ..................................................................................................................................................................... 34-35
14. Block Edit ......................................................................................................................................................................... 36
15-16. Learn Accept/Reject .................................................................................................................................................... 37
17. Recovery Speed ................................................................................................................................................................ 38
18. Bottlecap Reject ................................................................................................................................................................ 39
19. Hot Rock Reject ................................................................................................................................................................ 40
20. Sweep Speed ..................................................................................................................................................................... 41
21. Ground Filtering ............................................................................................................................................................... 42
Display
...................................................................................................................................................................................... 4322. Visual Disc. ....................................................................................................................................................................... 43
23. Icons .................................................................................................................................................................................. 43
24. V.D.I. Sensitivity ............................................................................................................................................................... 44
25. D.C. Phase ........................................................................................................................................................................ 45
26. Accumulate ....................................................................................................................................................................... 46
27. Average ............................................................................................................................................................................. 46
28. Fade ................................................................................................................................................................................... 47
Preamp Gain
............................................................................................................................................................................ 4829. Preamp Gain ..................................................................................................................................................................... 48
Multi Frequency Method ........................................................................................................................................................ 49
30. 2 Frequency (Best Data) ................................................................................................................................................... 49
31. 2 Frequency (Correlate) .................................................................................................................................................... 49
32. V.D.I. Normalization ......................................................................................................................................................... 50
33. 1 Frequency (3 kHz) ......................................................................................................................................................... 50
34. 1 Frequency (15 kHz) ....................................................................................................................................................... 50
EEPROM Programs ............................................................................................................................................................... 51-52
Program Settings Chart ......................................................................................................................................................... 53-54
Glossary ........................................................................................................................................................................................ 55
Warranty .................................................................................................................................................................................. 56-57
Service ......................................................................................................................................................................................... 58
Warranty(UK) ......................................................................................................................................................................... 59-60
Contents
Page2
Assembly
Chapter 1 DFX
™ AssemblyELBOW
CUP
STRAP
ELBOW CUP
FOAM PADS
INSIDE ELBOW
CUP
CONTROL BOX
“S” ROD
LOOP
CAMLOCKS CABLE
WASHERS BETWEEN
EACH LOOP
EAR & CLEVIS
DISPLAY
1/ PRESET PROGRAMS
2/ BASIC ADJUSTMENTS
3/ PRO OPTIONS
4/ TARGET ID NUMBERS
5/ TARGET ID ICONS
6/ TARGET ID SIGNAGRAPH
®7/ BATTERY STRENGTH
CABLE RETAINERS
BATTERY
COMPARTMENT
DOOR
BATTERY
COMPARTMENT
LATCHES
LOOP CONNECTOR
HEADPHONE
JACK
CLEVIS
LOWER
TOUCH PADS
SELECT PROGRAMS
ADJUST CONTROLS
LOOP OR SEARCH
COIL
Trigger behind display activates
depth reading and
pinpoint mode.
COIN PROGRAM
SQUEEZE & RELEASE TRIGGER
AFTER BATT. CHECK.
SCROLL OPTIONS
ATER BATT. CHECK USE
TO SCROLL CURRENT SETTINGS
OR MAKE ADJUSTMENTS
GROUND BALANCE ONLY
WHILE SEARCHING HOLD THE
TRIGGER AND PRESS
BATTERY CHECK
WHILE SEARCHING, HOLD THE
TRIGGER AND PRESS
REVERSE DISPLAY
WHILE SEARCHING. HOLD
THE TRIGGER AND PRESS
PRESS FOR
LIGHT/DARK BACKGROUND.
RELEASE TRIGGER
BACKLIGHT
IN SEARCH MODE, HOLD THE
TRIGGER AND PRESS
RELEASE TRIGGER
PUSH
AIR/GND BALANCE
IN SEARCH MODE PRESS
TO RE-AIR/GND BALANCE
VIEW ANGLE
WHILE SEARCHING HOLD
THE TRIGGER AND PRESS
RELEASE TRIGGER
PUSH
"HOT KEY" SHORTCUTS
Remove decal paper from the two rubber
bumpers. Install on the bottom of the control
box, one in each of the front corners (shown
below by "X"). Press in place and hold fi rmly
for a few seconds then release.
BOTTOM OF
CONTROL BOX
Twist and insert each end of
handle (provided) through
top of shipping carton into
second fl ap.
(CARRY CARTON)
3
Chapter 1 DFX
™ Assembly7.
Remove the protective paper from the two blackelbow cup foam pads. Carefully align pads on the
inside of the elbow cup, one on each side of the
center rod, and press fi rmly into place.
8.
Adjust the elbow cup strap so that it is looseenough for you to slide your arm in and out without
loosening each time you want to set the detector
down. The elbow cup strap provides extra
leverage and control. However, some prefer not to
use it.
9.
Install battery as described in the next section,decal facing down
, with plastic tab and steel contactsfacing toward inside of battery compartment.
10.
It should be noted at this point that the detectormay not work as expected indoors due to the high
degree of metals used in modern construction. It
is best to tune and practice out-of-doors to ensure
stable, predictable results. Additionally, freshlyburied
targets will not produce the normal depth
and discrimination results of targets that have been
naturally lost and settled in the ground. Due to the
abnormality caused by digging a hole in the ground
matrix, and the sophistication of the ground rejection
circuitry, it may take a number of years for
freshly-buried targets to respond at true depths and
discrimination accuracy. The best way to determine
true detection depth is in real search conditions.
11.
Your DFX is designed to automatically turnitself OFF if the trigger on the grip (or another
control) “is not used” for a period of 10-15
minutes. This protects the battery from damage
in case of an accidental turn on during travel or
storage. Normally something noteworthy of at least
pinpointing/depth reading (keeping the detector
operating) is encountered during each 10 minutes
of search. If searching an unusually area, free
of concentrations of metal, the DFX will make
a specifi c bleep upon turn off. Simply press ON
and squeeze and release the trigger on the grip
to resume searching. So long as a good battery
remains, the DFX returns to the exact settings prior
to turning itself off.
Assembly Instructions
1.
Remove all parts from shipping carton andcheck the assembly page to make sure all parts are
present.
2.
There are rubber washers between clevis/lowerrod and loop ears.
Use only nonmetallic washers,fi ber bolt, and thumbnut to secure loop/search
coil to clevis/lower rod.
3.
Unlock "S" rod camlock and insert clevis/lowerrod into curved "S" rod so that stainless steel
spring clip buttons line up and lock into one of
the adjustment holes in the curved "S" rod. Turn
camlock to secure. The second or third adjustment
holes are suitable for average size adults. Individuals
6' or taller should use the fully extended position.
Individuals well over 6' tall should purchase
the optional
Tall Man Rod.4.
Unravel loop cable and wind the cable aroundthe clevis and rod assembly, fi rst revolution over
the top of the rod. Wind cable all the way to the
top of the curved "S" rod, about fi ve revolutions.
Use the black cable retainers, one near the loop,
and one near the top of the curved "S" rod, to hold
the loop cable in place.
5.
Unlock control box rod camlock and insertcurved "S" rod so that stainless steel spring clip
buttons line up and lock into the rod on top of the
control box. The "S" rod is designed to curve up
toward the display. However, those who prefer to
sweep the loop close to their feet may desire to
assemble the "S" rod to curve down toward the
ground. Turn camlock to secure. Plug loop connector
into control box, screw lock ring to secure.
6.
Grip the instrument by the handle, with yourarm in the elbow cup with strap secure, and sweep
the loop/search coil over the fl oor. If the instrument
fi t feels uncomfortable, adjust the elbow cup
by removing and repositioning the bolt/thumbnut
and installing in one of the optional positions. If
necessary, readjust clevis/lower rod length with the
spring clip buttons so that the search coil can be
held near the fl oor without requiring stooping over.
4
Batteries
Chapter 2 DFX
™ BatteriesStandard Battery Holder
1.
The standard battery holder (blue decal) holdseight “AA” cell batteries. Alkalines are recommended
for use with this battery holder.
2.
Non-alkaline batteries can be used in this holder.When non-alkalines or rechargeable “AA”
cells are used, detecting time (before replacement/
recharge) may be reduced.
3.
"LOW BAT" will automatically appear on thedisplay when the batteries become too low to properly
operate the detector.
4.
The battery compartment opens by gently pullingdown on the front of each of the two latches
(on the bottom of the control box) releasing the
catch and hinging open the door.
The non-rechargeable battery holder can use many
different types of batteries, including rechargeable.
This holder is designed for standard size penlight
"AA" batteries which should be 50 mm ± .10mm.
Battery lengths shorter than this will likely cause
problems with this power supply.
When the instrument is turned on the battery voltage
will momentarily appear after the opening
display. The detector will then continue to the
MAIN MENU
. To recheck the battery voltage duringoperation, squeeze and hold the TRIGGER and
press the ARROW DOWN control.
ARROW DOWN
TRIGGER
UNDER
DISPLAY POD
BLUE DECAL
5
Chapter 2 DFX
™ BatteriesRechargeable Battery
A rechargeable battery (green decal) is provided
with your instrument. This battery can be recharged
hundreds of times as long as the battery hasn't been
stored for extended periods of time or overcharged.
Full charge can be achieved anytime during the
discharge cycle. When using the QUICK charge
setting (U.S.A. only) use the Charging Hours chart
on the following page for charge time. A full charge
will last ten to fi fteen hours of normal use.
Battery life will vary with temperature, the number
of targets found, and the exact settings used. Six
hours is not unusual for extreme high performance
settings, backlight use, or for batteries that have
experienced extensive use.
(
QUICK CHARGE is for USA ONLY. It is notavailable on 220-240 volt.)
Your charger has aswitch on it that selects the QUICK charge, or
OVERNIGHT charge options. Always check the
position of this switch prior to charging. Always
follow the charge hours on the chart on the following
page when the QUICK charge setting is used.
Overcharging with the QUICK charge setting will
damage the system.
Using the
Standard Battery Holder
1.
Slide open the battery holder lid (decal side ofbattery holder) by applying gentle upward
pressure on the tab of the door so that it unlocks.
Slide the door away from the battery box
exposing the cell positions.
2.
Remove any old cells from the holder. Note the(+) and (-) positions of each cell and the (+)
and (-) for each position marked inside the cell tray.
Install new “AA” cells
noting carefully the correct(+) and (-) positions.
If the cells are installed incorrectly, the detector
may require service by an Authorized
Service Center.
3.
Slide the door closed so that it snaps securely.4.
Insert the battery holder into the detector so thatthe decal is facing down, with the battery
holder door tab and metal contact points facing
toward the inside of the battery compartment.
Close the battery compartment door and secure
the two latches on the bottom of the case. Hook
the front of each latch fi rst, then press down on the
rear.
QUICK
CHARGE
OR OVERNIGHT
SWITCH
(U.S.A. ONLY)
GREEN
DECAL
BATTERY
CHARGER
BATTERY
COMPARTMENT DOOR
BATTERY HOLDER
WITH DECAL SIDE DOWN AND
METAL CONTACTS TO FRONT
CHARGER PLUG
6
Chapter 2 DFX
™ Batteries6.
The battery will lose its charge during storage.If stored inserted in your instrument, this loss
will be more noteworthy. It is recommended that
the battery be removed from the instrument during
periods of storage. It is not advisable to store
rechargeable batteries for long periods of time
without use. If however, storage is necessary, store
without a charge (discharged).
7.
Do not discharge the battery in devices otherthan your metal detector. Unnecessary discharging
and/or an absolute discharge will reduce battery
life and may damage the battery. Unlike older rechargeable
battery designs, the rechargeable battery
provided with your detector can be recharged at any
time.
Regardless of whether or not it already has apartial charge, memory will not occur.
8.
White's has provided the leading edge of rechargeablebattery technology with your instrument.
Disregard all advice which confl icts with the
above recommendations. Care for batteries provided
by other manufacturers, or with other White's
models, may vary.
Charging
1.
There is no harm chargingovernight using the
OVERNIGHT charge
setting regardless of the
battery's current condition.
However, before charging
with the QUICK charge
setting, determine battery
condition by inserting battery
into the instrument and
turning the instrument ON.
If the instrument will not
turn ON, or if voltage tests
eight volts or below, charge
fi ve hours with the QUICK
charge. If the battery voltage tests any other voltage,
refer to the Charging Hours chart above for
proper QUICK charge time.
2.
To charge, insert the charger plug into the batterypack jack, located near the plastic tab and
metal contact points.
3.
Plug the charger into a standard wall outlet. (110volts for USA models).
4.
Again, the QUICK charge setting uses the abovechart for a specifi c charge time. OVERNIGHT is
designed to charge the battery in as little as fourteen
hours. However, no harm will come to the system
leaving it charging for several days.
5.
It is normal for the battery and charger to getwarm during use. However, if either the battery or
the charger gets too hot to hold or deforms due to
the heat, discontinue use and return for testing.
7
Chapter 2 DFX™ Bat
teriesBattery Life & Memory
Volatile memory temporarily holds any program
changes or settings not yet saved in a Custom Program.
Short-term
or volatile memory is retained solong as a good battery remains in the detector. To
recover volatile memory immediately squeeze and
release the TRIGGER once the detector is turned
ON. If the battery is removed all volatile memory
is lost.
Long-term memory (programs saved inCustom Programs) is automatically saved for up to
ten years regardless of whether a battery is in the
detector or not.
When using fresh batteries, the voltage will initially
check somewhere in the 10 to 14 volt area. Unlike
standard batteries, the rechargeable battery voltage
will quickly drop to between 9 and 10 volts and
plateau there for most of its life. Once the rechargeable
battery voltage drops below this plateau, it will
quickly drop below a usable voltage level (eight
volts) and thus require a recharge.
Low Battery willautomatically appear on the display when the battery
reaches eight volts.
Like a personal computer, there are times (such as
low battery conditions) when the microprocessor of
a metal detector becomes out of sequence with the
rest of the circuitry. This is often noted by peculiarities
in the nondiscrimination or pinpointing (TRIGGER
squeezed) modes. Symptoms may be blaring
or silent non-discriminate or pinpoint modes, depth
indication inaccuracies or general abnormal operation.
To correct such diffi culties "re-boot" by:
1. Install a good battery.
2. Turn ON wait for MAIN MENU to appear.
3. Open battery door and remove battery while
detector is still ON.
4. Wait one minute, reinstall battery, turn
detector ON, and check for proper function.
Use of maximum backlight may reduce battery life
by up to 50%, depending on battery type.
Rechargeable batteries gradually deteriorate. As
they age they do not provide the life-per-charge
they did when new. This is expected, and not
grounds for replacement under warranty. Additionally,
a damaged initial cell, which is caused by overcharging
with the QUICK option,
is not replacedunder warranty
. Only cell failure through normaluse, or a defect due to a problem with a White's
warranted DFX
™ charger, is covered.8
Chapter 3 DFX
™ Quick StartDFX
™ Quick Start InstructionsAfter you have assembled the DFX
™ and inserted thebattery pack, follow these simple steps to start
treasure hunting!
DFX™ Quick Start
1
With the TRIGGER in the center position,press the ON/OFF control and an automatic
sequence will begin.
The display will momentarily show an
opening screen which lists the
softwareversion
.The display then shows a
battery checkscreen.
The last automatic display screen to appear
is the
MAIN MENU. Press the ENTERcontrol.
("BEEP")The Preset Program
COINS will appear onthe MENU. Press
ENTER . ("BEEP")You will be prompted to raise the search
coil (loop) to waist level. Press
ENTER .This
air balances the DFX™. ("BEEP")Next, the
ground balance prompt appearsasking you to lower the search coil (loop) to
the ground. Press
ENTER. Ground mineralizationwill be balanced out.
("BEEP")The last screen will be the live search
screen. You will hear the THRESHOLD
"hum". Sweep the search coil over the
ground and listen for a solid repeatable/consistent
beep, then look at the display. The
icons tell what likely coin lies below. V.D.I.
number/chart on top of control box and SignaGraph
® provide greater detail. Squeeze
the trigger for pinpointing and depth and it's
time to dig!
2
3
4
TRIGGER
UNDER
DISPLAY POD
CENTER
POSITION
1 2
3
4
(press ENTER)
(press ENTER)
5
5 6
(press ENTER)
6 7
7 8
(press ENTER)
8
(LIVE SEARCH SCREEN)
9
Chapter 3 DFX
™ Quick StartSearch Fundamentals
The loop/search coil must be in motion (sweeping
from side-to-side) for this instrument to
respond to metal.
Practice a smooth sweep ofthe loop from side-to-side keeping the loop close
to the ground throughout the swing.
Each pass ofthe loop should take approximately two seconds
from right to left, two seconds to return from left
to right.
Walk forward slowly. Take small steps no greater
than half normal strides. Make sure each pass of
the loop overlaps the last by at least half the length
of the loop. Do not lift the loop at the end of each
swing. Keep it close to the ground at all times.
To become comfortable with sweeping the loop
takes some practice. Try to loosen up and fi nd a
comfortable grip on the handle. Premature fatigue
may result from gripping the handle too tightly, improperly
adjusted rod or elbow support, and limited
body movement. Hold the handle loosely. Adjust
the rod and elbow support for comfort and keep the
elbow strap loose. Use your arm, shoulder and even
your back a little to allow a smooth even sweep of
the loop.
Now that you're sweeping the loop smoothly over
the ground, you will notice that the detector starts
making sounds
(beeps). Not all sounds are goodtargets; some trash targets also make the detector
beep.
As the loop is swept over the ground, ignore the
display and concentrate on the sounds the detector
makes.
As the loop is passed over metal that is likely trash,
the sound will be inconsistent. Trash targets typically
produce a shorter, sputter-type sound, that
is often broken or double in nature. Place a steelpop
bottlecap on the ground. Pass the loop over it
several times to become familiar with this sound at
different loop sweep speeds. Note that an aluminum
twist-off bottlecap
cannot be used as it is a differenttype of target. Also note that very old rusty bottle
caps may start reading as quarters due to the elimination
of the iron alloy through deterioration. Once
familiar with the sound typical bottle caps produce,
an operator may pass over such targets and continue
searching without consulting the display information,
saving more time for evaluating possible good
targets.
As the loop passes over metal that is likely a good
target, a more consistent and smooth sound will be
heard. A good target typically produces a longer,
more solid sound. Place a quarter on the ground
and sweep the loop over it several times to become
familiar with the sound of a good target.
Why Air/Ground Balance?
When the display prompts you to AIR BALANCE
by holding the loop at waist level and press ENTER.
The DFX
™'s circuits are being prepared forground balancing by measuring temperature and
other variables that affect electronic circuits. The
DFX
™ "beeps" and you lower the search coil to thedistance above the ground that you will be searching.
Press ENTER to have the DFX
™ "cancel/trackout" or GROUND BALANCE the ground mineralization.
The DFX
™ then automatically "tracksout" the varying mineralization as you continue to
10
Chapter 3 DFX
™ Quick StartLive Search Screen - what is it telling me?
VISUAL
DISCRIMINATION
INDICATION-V.D.I. NUMBER
("TARGET REFERENCE NUMBER")
POSSIBLE TARGET IDENTITIES
("ICONS")
SIGNAGRAPH BARGRAPH
1. V.D.I. Visual Discrimination Indication
("target reference number")
In the upper left hand-side of the display there is
a V.D.I. number that corresponds to the V.D.I.
SCALE painted on the top right-hand side of the
control box. It also corresponds to the Discriminate
Edit feature allowing you to reject or accept targets
based on their V.D.I. reference number. There are
"+" numbers for nonferrous (not of iron) targets,
and "-" numbers for ferrous (iron) targets. Rejected
V.D.I. numbers may not appear if the VISUAL
DISCRIMINATION feature is ON. Reasonably
consistent V.D.I. reference numbers (± fi ve digits),
in a desirable area of the chart is a vote for digging
the target.
2. Possible Target Identities ("Probable or most
likely target")
To the right of the V.D.I. number, possible target
identities will be represented graphically. These
graphics are called ICONS. A fairly consistent indication
of a desirable target is another vote to dig
the target. One or two possible target icons may
appear. There is signifi cance to which icon appears
fi rst. The fi rst target to appear is always the most
likely, the second is another possibility, slightly less
likely than the fi rst.
3. SignaGraph
®The SignaGraph
® at the bottom of the displayprovides a fi nal vote as to whether or not the target
should be dug.
A.
Sweep the loop over the target several timesand look at the SignaGraph
®. The SignaGraph®automatically clears itself (FADE RATE) so that it
doesn't fi ll the screen with information from past
loop sweeps. An operator has limited time to look
at the SignaGraph
®. If you want to look at theinformation again, sweep the loop over the target
several more times. The fading of the SignaGraph
®information can be slowed or speeded (FADE
RATE) to operator preference. This is completed
in the PRO OPTIONS under DISPLAY. Automatic
AVERAGING and/or ACCUMULATING of SignaGraph
®
information is also available (See PROOPTIONS).
B.
Valuable targets will show up on the positiveside of the graph. The positive area of the chart is
the section located to the right of the zero.
C.
Look for consistency. In ideal conditions, coinsand jewelry produce one or two bars to the right of
zero. Trash produces several bars, sometimes on
both sides of zero.
D.
In less than ideal conditions, coins may producea wider pattern of bars. Most trash targets produce a
recognizably different pattern than valuable targets.
E.
One of the most visual benefi ts of the Signa-Graph
® is the ability to show a smear patternon iron targets that often fool the other methods
of identifi cation. An iron target will likely show
defi nite bars on both the negative and positive sides
of the SignaGraph
®, often smearing all the wayacross the entire chart. Valuable targets should not
produce such obviously wide patterns. In very bad
ground conditions, a good target may have a few
small bar segments in the negative area due to mineralization.
However, the pattern will show mostly
positive bars, in a fairly narrow tall group.
MULTIFREQUENCY
METHOD
CURRENTLY IN
USE
11
Chapter 3 DFX
™ Quick StartLive Search Screen Samples
Nickel, or
possible ring.
Sometimes a
small (or half)
pull tab will
produce this
indication
Quarter.
Couldbe a worn half,
or large silver
jewelry.
Penny or a
dime.
If thescrew cap and
penny ICON
are displayed,
the target
could be an
Indian Head or
zinc penny.
Dollar.
Largenon-iron can
also produce
this indication
(large brass jar
lids).
IRON.
REJECTtargets will
produce only a
SignaGraph
® ifVISUAL DISC.
is ON
IRON.
+95ACCEPTED or
VISUAL DISC.
OFF
IRON.
-18ACCEPTED or
VISUAL DISC.
OFF.
Foil.
Possiblering. +10 ACCEPTED
or
VISUAL DISC.
OFF.
Pull tab.
Possiblering. +30
ACCEPTED or
VISUAL DISC.
OFF.
Ring.
Possiblepull tab. +48
ACCEPTED or
VISUAL DISC.
OFF.
12
Chapter 3 DFX
™ Quick StartPinpointing the Target
Once the decision has been made to dig, move the
loop off to one side of the target area, squeeze and
hold the TRIGGER on the handle, and "X" the loop
over the spot where you believe the target to be.
Note that the TRIGGER also has a locked forward
position that accomplishes the same thing as
squeezing and holding it.
While the TRIGGER is being held, the loop doesn't
need to be moving to detect the target. The loop
may be moved slowly over the area. The display
will indicate depth in inches and will also show
the strongest reading to aid in pinpointing exactly
where to dig. The shallowest reading on the depth
display, the loudest sound coming from the speaker,
and the two bars lining up with each other, indicate
the center of the target. Don't forget to "X" the
target as pinpointing cannot be accurate unless the
target is swept from at least two different directions.
Once pinpointing is complete, release the TRIGGER,
or return it to the center position.
Pinpointing takes practice. The standard loop provided
with the DFX™ is a high-powered, 12 inch
design. This harmonically tuned loop's strongest
traits are in the detection depth and ground coverage
areas. If pinpointing becomes diffi cult or critical
refer to the Advanced Pinpointing Techniques
on this page.
DEPTH SCREEN
DISPLAYED WHEN
THE TRIGGER
IS SQUEEZED
SQUEEZE TRIGGER
Advanced Pinpointing Techniques
1.
Targets that are near the surface, becausethey give a wider response, are harder to
pinpoint than deep targets. If the trigger is held
and the loop swept over the area, you may
note a shallow depth indication. Lifting the loop
slightly above the ground, releasing and resqueezing
the TRIGGER and again "X" ing the
target will aid pinpointing.
2.
In the Basic Adjustments, DC Sensitivity(non-motion) directly controls the pinpointing
mode. Lower DC Sensitivity settings pinpoint
shallow targets better.
3.
In the PRO OPTIONS under AUDIO, V.C.O.(Voltage Controlled Oscillator) signifi cantly aids
pinpointing.
4.
The depth reading has two indication bars.The top bar shows the current distance from
the target, and the bottom bar shows a memory
of the strongest reading. These two bars will be
even with each other when the loop is directly
over the center of the target.
"X" THE LOOP TO "PINPOINT"
THE TARGET
13
Chapter 3 DFX
™ Quick StartReady to Dig
Permission
- Prior to searching and digging youmust have permission to search private property,
from the owner or caretaker.
Laws
- Know the laws that apply to the area youare going to search. Laws vary a great deal with the
City, County, State, and Country, regarding the use
of metal detectors. Be respectful of private property,
public property, and the laws which govern the
use of metal detectors.
Tools
- Care must be taken to dig in a way that isfriendly to the landscape. Tools and methods vary a
great deal with the area, season, and types of target
you are recovering. Check with your dealer for
recommended tools and methods for your area.
Trash
- When searching, remove all trash you comeacross. This not only makes your future searches of
the area more productive; it promotes the hobby of
metal detecting.
Get Involved -
Your dealer knows of metal detectingclubs and organizations which promote and
protect the hobby. A club is a great way to not only
learn good detecting habits, but to gain permission
to search areas as a group as well as have organized
competition hunts.
Factory Preset Programs
Reached from the MAIN MENU, the factory PRESET
PROGRAMS give a quick start for:
Coins:
general purpose settings, discriminates (rejects)most common junk items like nails, foil, pull
tabs, and hot rocks; and responds to most coins and
large jewelry. Use in lawns, parks, and playgrounds
where lots of trash rejection is desired.
Coin & Jewelry:
less discrimination (less trashrejection), desirable because of the high degree of
variance found in jewelry alloys. More digging
required. Good program for lawns, parks, and playgrounds.
Use screen in conjunction with sound.
Jewelry & Beach
: similar to Coin & Jewelry, butsettings are optimized for salt water.
Relic:
even less discrimination than Coin & Jewelryor Jewelry & Beach, all types of metals except
small iron items like nails, and some stainless steel.
Brass, lead, aluminum, as well as copper, silver,
and gold all respond solidly. Ferrous (iron), such
as large nails, weapons, and cannon ball fragments
will also respond . Suitable for all signifi cant targets
and separates ferrous/nonferrous by display indications.
Prospecting:
NO AUDIO DISCRIMINATION. Allmetals respond with
beep. But V.D.I. numbers showonly for metals that could be gold. Dig only V.D.I.
number (possibility gold) targets and avoid iron.
Targets which cause an audio response, without
causing a V.D.I. number to appear on the display,
are not likely to be gold nuggets. Although highfrequency
gold-shooting detectors will respond
better, this mode will offer good results for the occasional
nugget hunter by responding to nuggets in
the six-grain and heavier category.
14
Chapter 4 DFX
™ Basic AdjustmentsBasic Adjustments
Basics of Basic Adjustment
After you have had some fi eld experience, you may
want to make some changes to the basic settings
of your detector.
From the search mode pressMENU
. At this point, the MAIN MENU will appearon the display. Use the ARROW controls to
move the pointer to Basic Adjustments,
and thenpress ENTER.
You may now use the ARROWdown
control to scroll through the Basic Adjustments.Using the fi rst adjustment screen (TARGET VOLUME)
as an example, the screens with a
graphiccontrol knob
require you to fififi rst press ENTERthen use the ARROW up and down controls to
adjust.
Note: when ENTER is pressed the squarearound the title moves to the setting, indicating you
are ready to make adjustments with the ARROW
controls.
After adjusting press MENU and usethe ARROW controls to continue viewing/setting
other Basic Adjustments, or squeeze and release the
TRIGGER to begin searching
Adjustment screens with an on/off selection need
only for you to press ENTER to change setting.
Pressing ENTER again changes back to the original
setting.
(press ENTER)
(press ENTER)
RECTANGLE AROUND
THE TITLE MOVES TO
THE SETTING
USE ARROW KEYS TO
ADJUST THE SETTING
UP OR DOWN
ADJUSTMENT
EXAMPLE:
TIP
- To quickly increase tomaximum, hold ENTER and
press ARROW up. To quickly
decrease to minimum, hold
the ENTER and press ARROW
down.
ADJUSTMENT
EXAMPLE:
1. TARGET VOLUME -
How loud a target beeps when detected.2. AUDIO THRESHOLD -
The slight hum or background sound heard continuously during searching.3. TONE (AUDIO FREQUENCY) -
Selects the frequency or pitch of sound the detector produces.4. AUDIO DISCRIMINATION -
The ability to reject trash, different sounds for different types of targets.5. SILENT SEARCH -
The ability to operate without the threshold or background hum.6. MIXED-MODE -
DC non-discriminate mode, working simultaneously with AC discrimination mode.7. A.C. SENSITIVITY -
Degree instrument is responsive to signals in the discriminate (motion) modes.8. D.C. SENSITIVITY -
Degree instrument is responsive to signals in non-discriminate (non-motion)modes.
9. BACKLIGHT -
Used in dark conditions to light the display improving visibility.10. VIEWING ANGLE -
Adjusts the display for low or high temperature visibility.Basic Adjustments - what do they do?
15
Chapter 4 DFX
™ Basic AdjustmentsMore Basics
All the MENU items are tied together so that the
ARROW up and down controls scroll through every
adjustment screen. If you continue to press the
ARROW
down you can go beyond the last BASICADJUSTMENT (View Angle) and into the PRO
OPTIONS. If the ARROW
up control is pressedafter VOLUME, you will be scrolling backwards
through the options starting with the end of the Preset
Programs, then the MAIN MENU, then the end
of the PRO OPTIONS.
An important feature of the ARROW controls; If a
BASIC ADJUSTMENT has been made (for example
Volume) and the trigger has been squeezed and
released to return to a search mode, you can return
to the volume adjustment simply by pressing either
of the ARROW controls. This shortcut returns to
the last adjustment that was made thereby allowing
an operator to switch directly from a search mode
to the adjustment currently being fi ne tuned. This
feature is desirable as you start using BASIC ADJUSTMENTS
or PRO OPTIONS that are located
further down the menu listings, or any adjustment
that may require some trial and error to fi nd the appropriate
setting.
If care is taken to use a desired adjustment screen
last (just prior to squeezing and releasing the TRIGGER
for a search mode), Custom Programs can use
this ARROW RETURN feature to allow quick easy
access to the most used feature. Use that feature
(adjustment screen) last, just prior to squeezing and
releasing the TRIGGER for searching. Then during
searching, press either ARROW to return directly to
that adjustment screen.
"Hot Key" Shortcuts
"HOT KEYS" will save time as they allow easy
access, from the search mode, to the most needed
adjustments. They are painted on the bottom of the
control box for fi eld reference.
NOTICE: "HOTKEY" shortcuts will not function from a cold start
(batteries just installed). To function from a cold
start the DFX
™ must be turned on and air/groundbalanced in any mode, then turned off. "HOT KEY"
shortcuts will then function.
COIN PROGRAM -
Squeeze & release TRIGGERafter automatic battery check.
SCROLL OPTION -
After battery check, use ARROWSto scroll all the current settings /menus.
AIR/GROUND BALANCE -
In search mode,press ENTER to re-Air/Ground Balance.
GROUND BALANCE ONLY -
While searching,hold the TRIGGER and press ENTER.
BATTERY CHECK -
While searching, hold theTRIGGER and press ARROW
down. Squeeze andrelease TRIGGER to return to searching.
REVERSE DISPLAY -
While searching, holdthe TRIGGER and press ARROW DOWN. Press
ARROWs for light/dark background. Light or dark
background will not change battery life. It will
make the display easier for some to read, particularly
in certain light conditions. It will work in combination
with backlight. Reversed display is only
accessible through the "HOT KEYS".
BACKLIGHT -
In search mode, hold TRIGGERand press MENU. Release TRIGGER, press
ARROWS to set.
VIEW ANGLE -
While searching, hold the TRIGGERand press ARROW
up. Release TRIGGER,press ARROWS to set.
16
A. LOAD
will activate a prior custom programstored in that position. After you have
SAVED or NAMED a program, you can select
LOAD and press ENTER, to use that program.
B. SAVE
saves your current settings in thatcustom position with either a generic name or
a prior custom name you may have applied.
Selecting SAVE and pressing ENTER saves
the current program.
C. NAME
is the preferred method. SelectNAME and press ENTER. You may now use
the ARROW and ENTER controls to name
your custom program. NAME automatically
SAVES, once you have chosen a name and
pressed MENU.
Custom EEPROM Programs
Saving Basic and Pro Option
adjustments for future use.
Save custom settings in any one of four EEPROM
program positions. They will remain permanently
in the DFX
™ memory regardless if the machineis turned off or the battery removed. Custom EEPROM
Programs can be changed at any time by
saving new settings over a previously saved custom
program. EEPROM is a special type of computer
memory made for this purpose, (Electrical-Erasable-
Programmable-Read-Only-Memory).
Chapter 4 DFX
™ Basic Adjustments1
SQUEEZETRIGGER
2
PRESS ENTER FOR PRESET PROGRAMS
SCROLL DOWN WITH ARROW KEYS
3
THEN PUSH
MENU
Once all of the changes you desire have been
made to any Preset Program or existing Custom
Program, squeeze and release the TRIGGER as if to
search.Then push MENU for MAIN MENU.
2.
Use the ARROW controls to select one of thefour Custom Programs then press ENTER.
You now must make one of three choices (use the
ARROW controls to make your selection):
4
PRESS ENTER
USE THE ARROW KEYS TO SCROLL THE
FLASHING SYMBOLS, PRESS ENTER
PRESS ENTER
PRESS MENU
1
1. 22. 33.17
Chapter 4 DFX
™ Basic Adjust-4. To NAME,
use the ARROW controls to select
the fi rst symbol, number, or letter of the name and
press ENTER. Use the ARROW controls to select
the second symbol, number, or letter of the name,
press ENTER. And so on using up to sixteen digits.
To leave a space, use the ARROWS to select the
point where no symbol or letter appears and press
ENTER. If you make a mistake and press ENTER
when the digit is not as you desire, simply keep
pressing ENTER until that digit is again fl ashing,
then use the ARROWs to select the correct digit and
again press ENTER. It is wise to name the custom
program something that relates to what it is used
for. For example "TRASHY PARKS", "GHOST
TOWN", "NIGHT HUNT", "COMPETITION", etc.
Once the name is fully assembled press MENU.
5.
Once you have SAVED and pressed ENTER, orNAMED and pressed MENU, there are four directions
you can go:
A.
Squeeze and release the TRIGGER to continuesearching using your new custom program.
B.
Press ENTER, select LOAD and pressENTER to continue searching using your
new custom program.
C.
Press MENU to return to choose or develop adifferent program than what you stored.
D.
Turn the detector OFF.6.
When the detector is turned back on, regardlessof whether a battery pack was left in the detector or
not, your custom program will be ready for you to
use again and again. Simply select it, press ENTER,
select LOAD, and press ENTER again. Follow the
on-screen instructions for Air/Ground Balance and
then search.
7.
If you SAVE or NAME a program, then decideyou no longer want to keep it, you can replace it
with a new program using the same procedure
as described above. The old program can only be
erased when a new program is stored in that position.
8.
You can NAME a custom program and at a laterdate replace the program while maintaining the
same name. Develop the changes fi rst to any program,
then use the SAVE method which maintains
the old name while storing the new program. To
keep the same program with a new name, fi rst
LOAD that custom program, Air/Ground Balance,
then press MENU and go to that custom position
and press ENTER. Now select NAME and press
ENTER. You can now develop a new name for the
old program.
Other Custom EEPROM
Program Info
Ground Balance
- When a Custom Program isstored, the Ground Balance setting last used with
that program is also stored. This has advantages
particularly for those who manually set the Ground
Balance for speciality applications. The automatic
Air/Ground Balance sequence will always override
manual settings. To access the last Ground Balance
setting used with a Custom Program, fi rst select the
desired Custom Program then press ENTER. Select
LOAD and press ENTER. Do not Air/Ground Balance
as the display suggests, simply squeeze and
release the TRIGGER. The last Ground Balance
setting will then be in use. If an appropriate Air/
Ground setting is not available, the instrument will
automatically require a new Air/Ground Balance.
Return ARROW Key
- The last Basic Adjustmentor Pro Option screen used is remembered by your
Custom Program. From the search mode, either
ARROW control will access the last Basic Adjustment
or Pro Option screen used. This allows easy
access to the most used adjustment.
Factory Preloaded EEPROM PROGRAMS
aredescribed on pages 53 and 54.
4
4.18
Chapter 4 DFX
™ Basic Adjustments1. Target Volume 48 - 63
How loud a target
beeps when detected.Select TARGET VOLUME with the ARROW
controls and press ENTER. The current volume
level sounds continuously. The number designating
the current level is shown on the right side of the
display. To the left, the graphic knob indicates the
relationship of the current setting to minimum and
maximum levels.
Use the ARROW controls to select the volume level
you desire. Volume level will select the loudest
possible sound a shallow target can produce. High
volume levels will slightly reduce battery life.
Press MENU and use the ARROWS to continue
viewing and/or adjusting Basic Adjustments, or
Squeeze and release TRIGGER to begin searching.
Tip
- Select the loudestcomfortable level, lower
with headphones, higher
without. Settings from
48 - 63 are available.
2. Audio Threshold
The slight hum or background tone which is normally
heard continuously during searching.
Select THRESHOLD with the ARROW controls,
and press ENTER . The current threshold level
will sound continuously. The number designating
the current level is shown on the right side of the
display. To the left the graphic knob indicates the
relationship of the current setting to minimum and
maximum levels. Note that the maximum threshold
level (42) is well below the minimum VOLUME
level. Thus with the THRESHOLD at maximum,
and the VOLUME at minimum, the detector will
still respond to metal. Use the ARROW control to
select the threshold level you desire. High threshold
levels will slightly reduce battery life.
Press MENU.
Tip -
Select the lowestlevel you can still hear.
Settings from 0 - 42 are
available
19
Chapter 4 DFX
™ Basic Adjustments3. Tone (Audio Frequency)
Selects the frequency or pitch of the sound the
detector produces.
Select TONE (AUDIO FREQ.) with the ARROW
controls and press ENTER. The current TONE
will sound continuously. The number designating
the current level is shown on the right side of
the display. To the left, the graphic knob indicates
the relationship of the current setting to minimum
and maximum levels. Low frequencies, from
about 100 down, begin to
pulse. Select an audiofrequency that you can hear comfortably and
provides the best defi nition for your ears. Press
MENU.
Tip -
If you have troublehearing high frequencies
select low TONE levels
(low numbers). If you
have trouble hearing low
frequencies, select high
TONE levels (high numbers).
Settings from 0-255
are available.
4. Audio Disc.
The ability of the detector to reject trash by
producing different sounds for different types
of targets. Trash is rejected by going silent or
producing a broken "cut-short" sound. Valuables are
detected by a smoother more solid sound.
Select AUDIO DISC. with the ARROW controls,
use the ENTER control to turn AUDIO DISC. ON
or OFF. When ON, specifi c targets will be accepted
or rejected based on the Program currently in use.
Audio Disc. turns ON or OFF the entire audio
discriminate feature. When OFF, all types of metals
produce an audio tone
(beep). Only by selection ofa different Program, or by entering the Pro Options
under Discrimination, can specifi c targets (V.D.I.
numbers) acceptance or rejection criteria be altered.
Press ENTER.
Tip -
Use AUDIO DISCON for trash rejection,
AUDIO DISC OFF for
detection of all types of
metals.
20
Chapter 4 DFX
™ Basic Adjustments5. Silent Search
The ability of the detector to be operated without
the threshold or background hum that is normally
heard continuously during operation. The
instrument is silent until a target is detected.
Select SILENT SEARCH with the ARROW
controls and use the ENTER control to turn
SILENT SEARCH ON or OFF.
To function, SILENT SEARCH requires AUDIO
DISC ON and MIXED MODE OFF. SILENT
SEARCH "ON" will automatically override both
AUDIO DISC and MIXED MODE menu selection
to perform the silent search function regardless
of your AUDIO DISC and MIXED MODE
selections. See chart on left side of this page.
In Pro Options the Discriminate feature can
be used to accept all metal targets while using
SILENT SEARCH. It is not possible to achieve
a non-motion searching mode with SILENT
SEARCH ON. When SILENT SEARCH is
ON the all metal pinpointing mode continues to
produce a threshold. This may not be noticed,
as once the pinpoint mode detunes for better
target center locating the threshold is not present.
However, releasing, re-squeezing, and holding the
TRIGGER with the loop at waist level a threshold
will be noted. Press ENTER.
Tip -
A threshold humis recommended as
it often fades over
rejected targets providing
information about targets
and ground conditions.
If the constant noise
bothers or distracts you
and reduced AUDIO
THRESHOLD doesn't
help, select SILENT
SEARCH.
AUDIO
DISC
SELECTION
ON
OFF
ON
OFF
ON
OFF
ON
OFF
SILENT
SEARCH
SELECTION
OFF
OFF
ON
ON
OFF
OFF
ON
ON
MIXED
MODE
SELECTION
OFF
OFF
OFF
OFF
ON
ON
ON
ON
RESULT
THRESHOLD
DISCRIMINATION
ALL-METAL
NON-DISCRIMINATION
SILENT SEARCH
DISCRIMINATION
SILENT SEARCH
DISCRIMINATION
MIXED MODE
MIXED MODE
SILENT SEARCH
DISCRIMINATION
SILENT SEARCH
DISCRIMINATION
21
6. Mixed Mode
A unique hybrid operating mode. It is an allmetal
(DC non-motion, non-discriminate) mode,
working simultaneously with a discriminate (AC
motion discrimination) mode. It is two modes, one
detecting everything and another discriminating,
operating at the same time.
Select MIXED MODE with the ARROW controls,
press ENTER control to turn MIXED MODE ON
or OFF.
AUDIO DISC needs to be ON and SILENT
Search needs to be OFF, for MIXED MODE to
perform properly. See chart on (page 20). MIXED
MODE ON will automatically override AUDIO
DISC selections to perform the MIXED MODE
function.
When Mixed Mode is on, all types of metals will
produce a sound (beep).
Discrimination Channel - When the loop is
in motion,
targets accepted by the discriminateprogram will produce a high-pitched
beep.Targets rejected by the discriminate program will
produce a lower pitched
beep. High-pitched orlow-pitched
beeps are directly determined by thediscrimination settings. An operator can select
discriminate settings through the selection of an
entire Program or by adjusting the accept and
reject V.D.I. numbers in the Pro Options under
Discrimination (EDIT).
All-Metal Channel -When the loop is not in
motion, or moved slowly,
all types of targetswill produce the same low-pitch
beep. Allmetalchannel will by nature detect deeper than
the discrimination channel. Deeper targets will
produce a lower volume sound when the loop is
moved slowly over the area.
Tip -
Advanced operators cangain extra depth by monitoring
the all-metal and discriminate
channels simultaneously,
checking depth and digging
targets too deep for the
discriminate channel alone.
For even more information
about the target, Pro Options
TONE I.D. and or V.C.O. can
be added to produce a truly
unique advanced users mode.
Chapter 4 DFX
™ Basic Adjustments22
Chapter 4 DFX
™ Basic Adjustments7. A.C. Sensitivity
Used to select the appropriate sensitivity (degree
that the instrument is responsive to signals) while
being used in the discriminate modes (those which
require movement of the loop).
Select A.C. SENSITIVITY with the ARROW
controls, and press ENTER. Use the ARROW
controls to set the level of sensitivity shown by the
number on the right. Press ENTER.
Sensitivity levels adjust detection depth and also
have a direct effect on detector stability. A.C.
SENSITIVITY levels should be selected carefully
to allow stable, predictable performance. Set a
lower level if the detector behaves erratically.
Tip -
Preset levels workwell for most conditions.
Reduced levels will
improve stability in diffi cult
conditions. Increased
levels will improve
detection depth if stability
can be maintained.
Tip-
Remember thatonce the TRIGGER is
squeezed and released
to go to a search mode,
you can return to the
last adjustment screen
used by pressing either
ARROW control. Settings
from 1 - 85 are availabLE.
8. D.C. SensitivityUsed to select the sensitivity (degree that the
detector is responsive to signals) while the
detector is being used in non-discriminate (ALLMETAL)
modes. These are modes that do not
require movement of the loop to respond. D.C.
SENSITIVITY fi ne tunes stability and pinpointing.
Select D.C. SENSITIVITY with the ARROW
controls, and press ENTER. Use ARROW
controls to select the desired D.C. SENSITIVITY
level shown by the number on the right. Press
ENTER. D.C. SENSITIVITY levels should be
selected carefully to allow smooth, stable and
predictable operation while allowing for reasonable
pinpointing.
A.C. and D.C. Sensitivity Adjustments are
traditionally the way to alter detection depth and
stability. There are other methods available in the
Tip -
Typically, lower D.C.SENSITIVITY settings
pinpoint shallow targets
far better than high
settings. High settings
will however, produce
more pinpointing (as well
as non-discriminate mode
'(ALL-METAL)' depth).
Pinpointing (TRIGGER
squeezed), MIXEDMODE,
and V.C.O.
AUDIO are dramatically
impacted by the D.C.
SENSITIVITY setting.
Settings from 1 - 60 are
available.
23
9. Backlight
Used in dark conditions to light the display,
improving visibility.
Select BACKLIGHT with the ARROW controls
and press ENTER. Use the ARROW controls
to select the desired BACKLIGHT level. The
BACKLIGHT level will be visible on the display.
The current level is shown on the right side of
the display. The graphic control knob shows the
relationship of the current setting to minimum
and maximum levels. Minimum is 0 (no light).
The maximum backlight setting will reduce
battery life by as much as 50% depending on the
type of batteries and how long it is used. Lower
BACKLIGHT settings will have signifi cantly less
drain on battery life.
When the detector is fi rst turned on, it is
normal for the backlight to be on during the
opening display and BATTERY CHECK. If the
BACKLIGHT is off, it will fade when the MAIN
MENU display appears. If the BACKLIGHT is
ON, it will continue until turned off manually or a
different program is selected. BACKLIGHT can
be saved as part of a custom program, for example
a NIGHT HUNT program.
When Backlight is ON and the TRIGGER
is squeezed and released to begin searching,
"BACKLIGHT ON" will appear continually on
the display to warn you of the extra battery duty.
EMERGENCY BACKLIGHT -
If in thedark you cannot see the display to turn the
BACKLIGHT on, holding the TRIGGER and
pressing MENU will bring up the BACKLIGHT
adjustment screen. Release the TRIGGER and
press ARROW
up to select a level you can see thedisplay. Squeeze and release the TRIGGER to
continue.
Tip -
Use only whenneeded, and only as bright
as needed, for acceptable
display visibility. Backlight
use will decrease battery
life. The brighter the level,
the higher the battery
usage. Settings from 0 - 6
are available.
CAUTION
If the instrument is turned ON and the
EMERGENCY BACKLIGHT sequence is
used, the BACKLIGHT will stay ON only
while you stay in that program. Pressing
MENU and selecting another program will
turn BACKLIGHT OFF, if BACKLIGHT
is not also ON in that particular program.
If in the dark at the time the instrument
is turned ON, you may need to squeeze
and release the TRIGGER and then
use the EMERGENCY BACKLIGHT
sequence. You can then fi nd the program
you desire, press ENTER, press ENTER
for Air Balance, and press ENTER for
Ground Balance. Use the EMERGENCY
BACKLIGHT ON sequence a second time
if the BACKLIGHT fades in that program.
Unlike past Spectrum
® instruments, theDFX
™ BACKLIGHT is no different thanany of the other adjustments. It can be
saved in the custom programs or short
term volatile memory. However, factory
preset programs use the OFF (0) setting
as a default (standard setting). Remember,
"Hot Keys" do not work from a cold start
(batteries just installed), see page 15.
Chapter 4 DFX
™ Basic Adjustments24
10. Viewing Angle
Adjusts the display for visibility in low or high
temperature conditions.
Select VIEWING ANGLE with the ARROW controls
and press ENTER, use the ARROW controls
to make changes. The current level is shown on
the right side of the display. The graphic control
knob indicates the relationship of the current setting
to minimum and maximum levels. Squeeze
and release the TRIGGER to resume searching.
VIEWING ANGLE has no impact on battery life.
EMERGENCY VIEWING ANGLE PROCEDURE
-If your detector has been in the cold or
heat prior to use, you may not be able to see the
display to adjust VIEWING ANGLE. Press the
ON/OFF control, hold the TRIGGER and press
ARROW
up. You can then use the ARROW controlsto fi nd a VIEWING ANGLE level that allows
you to read the display. Squeeze and release the
TRIGGER to begin searching. Like the BACKLIGHT,
you will lose your custom VIEWING
ANGLE setting if you change Programs. You
may need to use the EMERGENCY VIEWING
ANGLE PROCEDURE to see the display. Select
the program you desire, use the ENTER control
to enter, Air/Ground Balance, then again use the
EMERGENCY VIEWING ANGLE PROCEDURE
if the display is unreadable. VIEWING
ANGLE is preset at average levels in the factory
preset programs. The display may be unreadable at
either of the extreme settings in a particular environment.
Custom VIEWING ANGLE settings will
be saved when Custom Programs are stored for
future use.
Tip -
In cold temperaturesthe display typically will become
slower at responding.
Settings toward MAX (higher
numbers) speeds the
display and improves visibility
at cool temperatures.
In warm temperatures or
intense direct sunlight, the
display may become diffi cult
to see. Settings toward MIN
(lower numbers) will improve
visibility of the display
in all but extreme situations.
If large variations in conditions
result throughout the
day or nights search, you
may have to make several
VIEWING ANGLE adjustments
to maintain good
display visibility. Settings
from 1- 50 are available.
Chapter 4 DFX
™ Basic Adjustments25
Chapter 5 DFX
™ Pro OptionsPro Options
AUDIO
1. RATCHET PINPOINTING -
Pinpoint feature, automatically detunes for center location.2. S.A.T. SPEED -
Self Adjusting Threshold or Auto-tune, automatically maintains threshold.3. TONE I.D. -
Assigns each V.D.I. target number its own special tone or sound.4. V.C.O. -
Pinpoint or non-discriminate feature, increases pitch or tone with target strength.5. MODULATION -
Motion modes produce the same, or different volume, based on target depth.G.E.B./TRAC
6. AUTOTRAC
® - Automatically updates Ground Balance during searching.7. TRAC VIEW -
TRACK appears on right side of display during AUTOTRAC® adjustments.8. AUTOTRAC
® SPEED - Dictates when AUTOTRAC® adjusts Ground Balance.9. AUTOTRAC
® OFFSET - Positive or negative AUTOTRAC® (over, or under kill).10. TRAC INHIBIT -
Prevents tracking the ground during target detection.11. COARSE G.E.B. -
(Manual Ground Balance) Coarse viewing, or overriding automatic.12. FINE G.E.B. -
(Manual Ground Balance) Fine viewing, or overriding automatic.DISCRIMINATION
13. DISC. EDIT -
Change V.D.I. (target reference numbers) accepted (detected), or rejected status.14. BLOCK EDIT -
Speeds EDIT by dragging ACCEPT or REJECT with ARROW controls.15. LEARN ACCEPT -
Target samples can be used to show or teach ACCEPT discrimination.16. LEARN REJECT -
Target samples can be used to show or teach REJECT discrimination.17. RECOVERY SPEED -
Speeds target responses, so close together targets each respond.18. BOTTLECAP REJECT -
How strongly the instrument rejects or breaks up on iron.19. HOT ROCK REJECT -
Degree the instrument is responsive to signals in the +95 (hot rock) category20. SWEEP SPEED -
Adjust signal sampling width thus the ideal loop/search coil sweep speed.21. GROUND FILTERING -
How much circuitry (high-pass fi ltering) used to separate ground/trash signals and targets.DISPLAY
22. VISUAL DISC. -
Rejected V.D.I. numbers and ICONS do not appear on display.23. ICONS -
Graphic display representation of metal targets, ON/OFF.24. V.D.I. SENSITIVITY -
Response intensity to produce a display indication & 3rd V.D.I. digit@ 86 and higher.25. D.C. PHASE -
Measurement of ground, or metal target, during pinpointing.26. GRAPH AVERAGING -
SignaGraph® information collects over multiple loop passes.27. GRAPH ACCUMULATING -
Emphasizes common or predominate SignaGraph®.28. FADE RATE -
Clears or fades noncurrent SignaGraph® information (bars).PREAMP GAIN
29. PREAMP GAIN -
Selects the intensity of the signal received from the loop.MULTI FREQUENCY METHOD
30. 2 FREQUENCY (BEST DATA) -
Transmits and processes at both 3kHz and 15 kHz frequencies (salt eliminated).Automatically chooses data from the most reliable frequency (based on both magnitude and phase) for each specifi c target.
31. 2 FREQUENCY (CORRELATE) -
Transmits and processes at both 3kHz and 15 kHz frequencies (salt eliminated).Compares data at 3 kHz and 15 kHz. Target signals that do not provide reasonably predictable information at both are automatically
rejected. Iron typically doesn't compare predictably between frequencies, improved iron rejection can be expected.
32. V.D.I. (NORMALIZED) -
2 Frequency modes (Best Data and Correlate) automatically have V.D.I Normalized ONas it is required for these modes to operate predictably. Differences at 3 kHz and 15 kHz skew the well known traditional (6.59
kHz) V.D.I. chart/numbers painted on the top of the DFX control box. Normalization recalculates signals for this traditional
V.D.I. number chart. OFF expands/compresses portions of this V.D.I. scale (depending on the 1 frequency used.).
33. 1 FREQUENCY (3kHz) -
Operates at 3 KHz providing for superior high iron mineral use (no salt present) particularlyfor high conducting silver/copper alloys. Normalized ON maintains traditional (6.59 kHz V.D.I. chart/numbers. Normalized OFF
signifi cantly expands higher end of V.D.I. chart/numbers compressing lower end of the scale.
34. 1 FREQUENCY (15 kHz) -
Operates at 15 kHz providing in lower mineralized areas (no salt present) particularlyfor lower conducting gold/nickel alloys. Normalize OFF signifi cantly expands lower end of V.D.I. chart/numbers compressing
higher end of the scale.
(Overview)
26
Basics of Pro Options
The
PRO OPTIONS are used to make the moreintricate adjustments available on this model. The
PRO OPTIONS are divided into fi ve major categories
of menus, structured similar to the Basic
Adjustments. Methods of entry, adjustment, exit,
and reentry remain the same.
To enter the PRO OPTIONS from a search mode,
press MENU and the MAIN MENU will appear.
Use the ARROW controls to select PRO OPTIONS
and press ENTER. The PRO OPTIONS menu will
appear on the display. There are two pages to the
PRO OPTIONS menu (PG. 1/2
Page one of two).The ARROW controls are then used to select the
desired PRO OPTION category.
The six major categories have options specifi c
to their titles. For example, all the options under
AUDIO have to do with the way the audio circuits
of the instrument behave. Once a category has been
selected and the ENTER control pressed, the ARROW
controls can then be used to scroll through all
the options even beyond that category i.e., beyond
PRO OPTIONS, back to PRESET PROGRAMS,
and BASIC ADJUSTMENTS. The categories will
only reappear if MENU is again pressed, or at specifi
c times during scrolling (to offer short cuts).
From this point forward, we will assume that you
know how to use the MENU control, the Arrow
Controls to make a selection, the ENTER control
to enter or select that option, the Arrow Controls to
make adjustments, and the MENU to exit. Remember,
squeezing and releasing the trigger returns to a
search mode. Arrow Controls can be used to return
from the search mode to the last menu or adjustment
display used.
Chapter 5 DFX
™ Pro OptionsPro Options
Be aware that changes you make to a
Program are only in effect as long as
you continue using that Program. If the
detector is turned OFF, the Trigger must
be squeezed and released to recover short
term (volatile) memory upon turning the
detector ON. If you want to keep the
changes you made to a specifi c program
over an extended time period (days or
weeks), or through battery changes, the
entire Program must be saved in a Custom
EEPROM Program position.
CAUTION
MAIN MENU Screen
Pro Options
Sub Menu #1
Pro Options
Sub Menu #2
27
Chapter 5 DFX
™ Pro Options1. Ratchet Pinpointing
Pinpointing feature, automatically detunes for easy
target-center locating.
ON - Automatically aids in pinpointing. When the
TRIGGER is squeezed and held for pinpointing,
RATCHET PINPOINTING will shrink the size of
the signal as the loop is passed over the target area
several times. The signal will not fade completely
unless the loop is moved too far away from the
target center.
OFF - When OFF, the signal will remain original
size giving some indication of its size and shape.
Manual shrinking is completed by squeezing and
releasing the TRIGGER several times as the loop
is passed over the target. Manual shrinking can
completely eliminate the target. If the target no
longer responds after manual shrinking, move the
loop away from the target, squeeze and release the
TRIGGER, and again sweep the loop over the area.
If the target is a metal, it should again respond.
Tips -
Use the ON settinguntil experienced at
pinpointing.
(Audio section)
2. S.A.T. Speed
Self-Adjusting Threshold (auto-tune) smooths the
THRESHOLD, OFF (0), or ON (1-10).
Without S.A.T. SPEED (a setting of 0), changes in
the ground (and the passage of time) will tend to
produce changes in the THRESHOLD sound. The
TRIGGER will have to be squeezed and released
repeatedly to maintain the THRESHOLD. This is
particularly noticeable in non-discriminate modes,
although S.A.T. SPEED will also tend to add
stability to discriminate modes. S.A.T. SPEEDs
1 through 10 will automatically correct for such
THRESHOLD changes.
S.A.T. (auto-tune) is a feature that has been used on
metal detectors dating back to the 1970's. It adds
a loop-motion requirement to modes which are
ordinarily non-motion. It is also known to produce
some variations in the responses to hot rocks (rocks
more mineralized than the surrounding ground)
which change with different speed selections.
Only enough S.A.T. SPEED required to maintain
stability is recommended. Typically normal coin
searching requires slower (lower number) speeds,
beach hunting and relic hunting require slightly
faster speeds (higher numbers), and prospecting
requires the fastest settings (highest numbers).
Tips -
Recommended for most conditions as it providesgreater stability particularly in non-discriminate modes or
when sensitivity levels are maximized. Typically, faster
S.A.T. SPEEDs (higher numbers) improve performance
in more mineralized ground. Slower S.A.T. SPEEDs
(lower numbers) improve performance in milder ground
conditions. Settings from 0 - 10 are available.
28
Chapter 5 DFX
™ Pro Options3. Tone I.D.
Assigns each V.D.I. number its own distinct tone or
pitch. Target ranges can easily be identifi ed by their
sound. The higher the V.D.I. number, the higher the
pitch of their sound. Reject targets still break up or
"cutout".
Tone I.D. is used in the discriminate or motion modes.
When ON, each V.D.I. target number has its own
audio frequency or pitch (191 different pitches). The
higher the V.D.I. number, the higher the pitch. Where a
target indicates on the V.D.I. scale can be immediately
recognized. The sound that rejected targets produce
will still be canceled or modifi ed (broken up) by the
discriminate circuit.
The 191 different pitches or tones activated with
TONE I.D. cannot be adjusted as to their pitch. Each
V.D.I. number's sound is predetermined by the factory
and is not adjustable, nor will they shift with TONE
(AUDIO FREQUENCY) adjustments.
Tips -
Great for coin, jewelry,and relic searching.
Can be used in combination
with MIXED MODE
.4. V.C.O.
Voltage Controlled Oscillator produces a higher pitched
tone the stronger the target becomes.
Voltage Controlled Oscillator is a feature that will only
work in the non-discriminate modes. When it is ON,
the stronger the response the higher the pitch of the
sound. An excellent aid in pinpointing, V.C.O. will only
function when the trigger is squeezed for pinpointing
when activated in a discriminate mode. It will function
full time in the non-discriminate (ALL-METAL)
modes.
D.C. SENSITIVITY settings will dramatically change
the performance of V.C.O. D.C. SENSITIVITY settings
above a level of 35 may peak the audio pitch too
soon to allow V.C.O. to be useful. D.C. SENSITIVITY
settings of 35 or below (lower numbers) are recommended,
particularly in trashy areas where targets are
close to each other.
Tips -
The best aid availablefor pinpointing. Also
can work well in combination
with MIXED MODE to
more easily indicate when
the non-discriminate channel
is operating.
(Audio section)
5. Modulation
Allows motion modes to produce different volume
levels based on target depth.
Modulation is used in the discriminate or motion
modes. When ON, it allows the depth of the target to
dictate the volume of the response. Thus deep targets
can be easily recognized by their lower-volume sound.
If OFF, the discriminate or motion modes will produce
the same volume of response on all detected targets
regardless of depth. The use of MODULATION allows
for the singling out of deep targets in the standard
discriminate mode. It may save time by eliminating
the checking of each target with the depth indication in
the pinpoint mode.
Tips -
If you have excellenthearing and want to single
out deep targets by their
lower-volume responses,
use modulation. ON is the
default (standard setting)
for all factory Preset Programs.
If your hearing isn't
the best, the OFF setting is
recommended.
29
6. AutoTrac
®AUTOTRAC
® allows the instrument to automaticallyreadjust the Ground Balance setting during
searching. This readjustment allows for natural
occurring changes in the ground mineral of an
area. By maintaining an accurate Ground Balance,
detection depth and stability are enhanced. AUTO
TRAC
® is recommended for typical search conditions.If, however, a great deal of decomposed
man-made iron is encountered, AUTOTRAC
® OFF,or a reduced AUTOTRAC
® SPEED is advised.AUTOTRAC
® operation is affected by TRACINHIBIT.
Tips -
Use ON for mostsearch conditions.
(G.E.B./Trac section)
7. Trac View
When ON, "TRACK" appears on right side of display
when AUTOTRAC
® makes adjustments to theGround Balance setting.
TRAC VIEW offers a way to observe Autotracking.
When ON, "TRACK" will appear momentarily
on the right-hand side of the display just above the
SignaGraph
® while AUTOTRAC® is adjusting.This information is valuable when attempting to
determine an appropriate Trac Speed. It may also
be a valuable aid in determining the relative ground
conditions. Reoccurring "TRACK" would indicate
diffi cult ground. In average ground it is desirable
to see some
tracking occur (see TRAC SPEED).Tips -
Use when experimentingwith different
TRAC SPEEDs to determine
if, and how often,
AUTOTRAC
® automaticallyadjusts Ground Balance.
Chapter 5 DFX
™ Pro Options30
Chapter 5 DFX
™ Pro Options8. Trac Speed
Dictates when AUTOTRAC
® adjusts Ground Balance.Trac Speed allows adjustment of the amount of
ground mineral change required to cause Autotracking
to occur. At slower speeds (lower numbers)
it takes a signifi cant change in the ground to
cause tracking to occur. At faster speeds (higher
numbers) it takes very little change in the ground
mineral to cause tracking to occur. The end result,
more tracking occurs at higher numbers than at
lower numbers. Too much tracking can cause errors
in the ground balance setting. Not enough tracking
can result in the ground balance setting never
catching up with changing ground. TRAC VIEW
is used to see how much tracking is occurring.
Generally, a faster (higher number) TRAC SPEED
is needed for more consistent ground conditions.
Slower TRAC SPEEDS (lower numbers) is needed
for more inconsistent ground conditions. "TRACK"
appearing every three to fi ve sweeps of the loop is
the ideal setting when the ground conditions will
allow.
Tips -
It is desirable toselect a TRAC SPEED that
tracks the ground once
every three to fi ve sweeps
of the loop however, this
may not be possible in
extremely consistent, or
extremely inconsistent
ground conditions, which
may TRAC less or more
than this desired standard.
Settings from 1 - 20 are
available.
(G.E.B./Trac section)
31
9. Trac Offset
Allows AUTOTRAC
® to track ground mineralseither positive or negative in relationship to the
correct setting (under, or over kill).
TRAC OFFSET allows the AUTOTRAC
® featureto track the ground slightly more or less than what
would normally be considered perfect, mostly for
experts that prefer a slight offset.
A slightly positive offset can be used to enhance
the responses of small metals (gold nuggets) in
highly-mineralized ground. Positive is indicated by
a slight increase in threshold as the loop approaches
the ground in the all-metal mode. Discrimination
and depth may also be improved.
A negative offset may be used to eliminate particularly
troublesome "hot rocks" in areas that are
otherwise diffi cult to search. Negative offset is indicated
by a loss or slight decrease in the threshold
as the loop approaches the ground in the all-metal
mode.
Tips -
Recommended onlyfor experienced operators
who fully understand
ground rejection. Settings
from -10 - +10 are available.
(G.E.B./Trac section)
10. Trac Inhibit
Prevents AUTOTRAC
® from tracking the groundduring target detection.
TRAC INHIBIT ON prevents the AUTOTRAC
®feature from altering Ground Balance during the
detection of targets. This prevents the possibility
of tracking to the corrosion associated with most
metals. TRAC INHIBIT ON is recommended for
most searching conditions. Some metals do not
corrode (GOLD) and since tracking is extremely
important in high mineral conditions, the ability
to turn TRAC INHIBIT OFF is available. OFF is
automatically selected in the Prospecting Program
and is recommended for prospecting.
Tips -
ON for most searchconditions, OFF for prospecting.
Chapter 5 DFX
™ Pro Options32
11. Coarse G.E.B.
(Manual Ground Balance) allows viewing the current
automatic Ground Balance setting (Air/Ground
Balance) and/or manual overriding of the automatic
Ground Balance.
COARSE & FINE G.E.B. (Ground Exclusion
Balance, or ground rejection) allows manual override
of the automatic balancing features to select a
specifi c Ground Balance setting. COARSE allows
major adjustments. FINE allows minor adjustments
near the COARSE setting.
Before attempting manual Ground Balance adjustments,
turn off AUTOTRAC
® since it will alterany manual changes you make. Manual Ground
Balance will begin at the setting selected by the
automatic (Air/Ground Balance) sequence. An
Automatic Air/Ground Balance performed after
manual adjustment will cancel the manual setting.
To maintain a manual setting, the Automatic Air/
Ground sequence must be avoided by squeezing
and releasing the TRIGGER when, and if, the Air
Balance instruction appears. Air Balance instructions
may appear during Basic Adjustment or Pro
Options selections following the manual adjustment.
When manually adjusting the Ground Balance, it
is necessary to make an adjustment in COARSE
and/or FINE, then squeeze and release the TRIGGER.
The TRIGGER can be held in, and the loop
lowered and lifted over the ground to check for a
change in sound which would indicate imperfect
Ground Balance. To return to the Ground Balance
display for further adjustment, press either of the
ARROW controls. When perfectly Ground Balanced
in a search mode, the TRIGGER can be
squeezed and held, and the loop lowered and lifted
Tips -
Use for controlledreactions to specifi c minerals
or hot rocks. Settings
from 0 - 255 are available.
(G.E.B./Trac section)
Chapter 5 DFX
™ Pro Options33
Chapter 5 DFX
™ Pro Options12. Fine G.E.B.
FINE G.E.B. is used to make smaller adjustments
to the Ground Balance range on either side of the
COARSE setting. The FINE setting combines
with the COARSE setting to determine the actual
ground rejection level. To determine exactly what
level the automatic Air/Ground sequence selected,
it is necessary to check both COARSE and FINE
levels.
Manual Ground Balance will rarely be used for
perfect balancing as the automatic balance is
extremely reliable. It is generally used to offset
Ground Balance for the same reasons AUTO
TRAC
® OFFSET is used.In COARSE or FINE, lower numbers indicate a
Ground Balance setting toward the negative side
of the V.D.I. scale (iron). Larger numbers indicate
a Ground Balance setting toward the positive side
of the V.D.I. chart (salt). Bad ground conditions
(high mineralization) may be described as either
magnetic
(negative or low numbers) or conductive(positive or high numbers). COARSE and
FINE settings of 0 represent a ground rejection
similar to a V.D.I. number of -95. COARSE and
FINE settings of 255 represent a ground rejection
level similar to a V.D.I. number of +10. This V.D.I.
range from -95 to +10 represents the ground rejection
range of this instrument. If ground balance
(either automatic or manual) occurs near the 255
COARSE setting, signifi cant loss in sensitivity can
be expected to targets which indicate in the V.D.I.
number range of 1 to 10. However, manual ground
balance doesn't exactly work like a discriminator,
where V.D.I. numbers are simply REJECTED. The
actual phase of Ground Balance is out of sequence
with most targets; thus some responses will occur
even if COARSE & FINE G.E.B. are matched
exactly to a particular targets V.D.I. number.
(G.E.B./Trac section)
Tips -
Use for controlledreactions to specifi c
minerals or hot rocks. The
Fine G.E.B. control when
adjusted to the top of the
scale, 255, will automatically
bump up the Coarse
G.E.B. setting by one
increment so that fi ne adjustment
can continue uninterrupted.
When adjusted
to the bottom of the scale,
0, Coarse G.E.B. setting
is automatically bumped
down by one increment so
that fi ne adjustment can
continue uninterrupted.
The entire Coarse G.E.B.
range is available on the
Fine G.E.B. control made
possible by this mechanism.
Settings from 0-255
are available, coarse and
fi ne.
34
Chapter 5 DFX
™ Pro Options13. Disc. Edit
Allows for changing which targets V.D.I. or reference
numbers are ACCEPTed (
detected), or REJECTed,(
discriminated out) within the currentProgram you are using.
Select DISC. EDIT and press ENTER. Now use
the ARROW controls to view the V.D.I. numbers
from negative -95 to positive +95 that appear on
the right side of the display. These are the same
reference numbers that are listed on the top righthand
side of the control box (V.D.I. SCALE or target
chart). For each V.D.I. number, a √ will appear
to the left indicating whether the current program
will ACCEPT or REJECT targets that display that
number.
Use the ENTER control to change any desired
V.D.I. number to ACCEPT or REJECT status.
If you do not save the entire Program into a Custom
Program, the changes you make in EDIT are
only in use as long as you continue to use that
program. The only exception being the temporary
short-term or volatile memory as previously described.
If you make EDIT changes in Coin, and
then switch to COIN & JEWELRY, you lose all
editing you completed in the Coin Program. Each
time a factory Preset Program is ENTERed, all
unsaved settings are overwritten by the factory
recommended settings. Only the Custom Programs
will save your custom settings through Preset Program
selections.
Accepting a wider range of V.D.I. numbers will
have an impact on detection depth, particularly for
very deep targets that are diffi cult for the display
to identify. Positive +95 is one of the most signifi -
cant V.D.I. numbers. Some Preset Programs are set
so that the positive +95 V.D.I. number is rejected.
The display uses positive +95 for many different
DISCRIMINATION -
Will have a greaterimpact on how the instrument operates
than any other feature. Audio Discriminate
ON/OFF is located in the BASIC
ADJUSTMENTS, (page 19).
DISC. EDIT
and BLOCK EDIT areexceptions to the keystroke rule in that
they do not have a graphic control knob.
However, ENTER must still be pressed
before adjustments are possible
.(Discrimination section)
Tips -
The factory PresetPrograms have all the major
DISCRIMINATION EDIT
setups already defi ned and
ready for you to use. Major
changes in ACCEPT and
REJECT targets should be
selected by choosing one
of these factory programs.
EDIT allows customizing for
specifi c or unusual targets
you may want to either ACCEPT
or REJECT. Settings
from -95 - +95.
35
types of targets it cannot readily identify. Therefore,
if positive +95 is ACCEPTed, questionable
targets may be dug that indicate this number and
can produce some interesting recoveries.
A goodtip regarding positive +95: If a target indicates
95, and the depth display indicates it as being fairly
deep;
dig it. If the depth display indicates it asbeing fairly shallow, it is more likely to be trash or
a hot rock. HOT ROCK REJECT in the Pro Options
has 20 levels available for the acceptance or rejection
of +95. An operator can adjust HOT ROCK
REJECTION to suit personal preference and area
demands. (See page 42.)
The fi rst 30 to 40 negative numbers below zero also
impact detection depth. Most iron indicates further
into the negative numbers. Thus the fi rst 30 to 40
negative numbers can often be ACCEPTed without
digging much iron. ACCEPTing from the positive
numbers down as low as minus 30 to 40 has
the largest impact on the lower end of the positive
numbers. Sensitivity to small jewelry is increased.
However, sensitivity to foil is also increased. On a
beach or in a park that has lots of small foil, ACCEPTing
down to minus 30 to 40 may not be practical.
While ACCEPTing these minus numbers, a
reduced sensitivity setting may help eliminate some
of these small bits of unwanted foil.
ACCEPTing all V.D.I. numbers will produce the
best overall detection depth however, with the
amount of trash in most areas, searching with no
rejection is seldom practical. TONE I.D. is a more
practical choice. The idea of discrimination is to
ACCEPT V.D.I. numbers most likely to be valuables
and to REJECT the V.D.I. numbers most
likely to be trash. Digging ease, and acceptability in
an area will also decide the amount of ACCEPTed
V.D.I. numbers desired. No metal detector can
reject all trash while accepting all valuables. The
deeper you want to detect, the more trash you will
need to accept and dig.
The detector sees metals electronically; thus some
valuable and non-valuable targets may look identical
to the detector. To select ACCEPT and REJECT
V.D.I. numbers is to gamble that the areas you
select for
ACCEPT will be good targets, and thearea you select for
REJECT will be trash targets.A factory program which uses the law of averages
usually produces more good targets than trash. The
EDIT feature allows you to fi ne-tune the ACCEPT
and REJECT settings for your area and types of
desired targets, further improving these odds.
Chapter 5 DFX
™ Pro Options36
Chapter 5 DFX
™ Pro Options14. BLOCK Edit
Speeds major EDIT changes by
dragging ACCEPTor REJECT with ARROW controls.
Allows major EDIT changes to be completed
quickly. EDIT is for individual V.D.I. number
changes and/or viewing of the current settings.
BLOCK EDIT is for changing multiple V.D.I.
numbers, or ranges.
Select BLOCK EDIT with the ARROW controls
and press ENTER. The ENTER control can be
used to select either ACCEPT or REJECT. The
ARROW controls can then be used to drag that
ACCEPT or REJECT status as far as desired
through the V.D.I. number range. When a V.D.I.
number or range of numbers appear that you want
set differently, stop dragging with the ARROWs,
press ENTER to change the ACCEPT/REJECT
status, and then drag that new status as far as you
desire. ENTER changes ACCEPT/REJECT; ARROWS
drag that ACCEPT/REJECT status; ENTER
again changes ACCEPT/REJECT; ARROWS
drag that new ACCEPT/REJECT status, etc.
BLOCK EDIT not only saves time if large sections
of the V.D.I. target numbers are to be changed, it
also allows peace of mind in the certainty of how
all the V.D.I. numbers are set. In the same amount
of time it takes to view all the V.D.I. number's current
status in regular EDIT, you can set them the
way you desire in BLOCK EDIT.
(Discrimination section)
Tips -
If more than a fewV.D.I. numbers are to be
changed, use BLOCK EDIT.
Settings from -95 - +95.
Caution:
You cannot viewthe current settings or the
recent changes you have
made while still in BLOCK
EDIT. You must press
MENU, ARROW up to EDIT
and ENTER. The arrows
can then be used to view
the settings. Whenever
the arrows are used while
in BLOCK EDIT, you will
change every V.D.I. number
viewed to the ACCEPT or
REJECT status whichever
one appears on the display.
37
Chapter 5 DFX
™ Pro Options15-16. Learn Accept/Reject
Specifi c target samples can be used to show or
teach the discriminator what metal targets you
desire to ACCEPT or REJECT.
Select LEARN ACCEPT or LEARN REJECT with
the ARROW controls and press ENTER to turn
LEARN ON. The current selection is indicated by
the √ mark in square on the left of the display.
Once ON:
1.
Squeeze and release the TRIGGER.2.
Show metal target sample or samples tothe instrument by sweeping them one at a
time in front of the loop until the desired
accept or reject sound is heard.
3.
Press either ARROW control to return tothe LEARN selection display.
4.
Press ENTER control to select LEARNOFF.
5.
Squeeze and release the TRIGGER toreturn to a searching mode.
(Discrimination section)
Tips -
If searching for one specifi ctarget and an exact sample is available,
BLOCK EDIT everything for reject then
use LEARN ACCEPT to accept only
that specifi c target. If using a standard
program and a specifi c unwanted
trash target is being detected, use the
LEARN REJECT to change the program
to reject it.
If you do not return to the LEARN
selection screen and turn LEARN OFF,
the detector will continue to learn (ACCEPT
or REJECT) every metal target it
encounters.
Selecting LEARN OFF afteryou have learned a target is extremely
important.
Iron alloys, such as steel bottle caps
or nails, should never be used for this
LEARN method of programming. Because
of their inconsistent V.D.I. indications,
iron alloys tend to scatter or otherwise
confuse the discriminate program.
If this occurs, it is best to turn the detector
OFF, back ON, and re-ENTER the
desired Program to return to the original
factory preset discriminate settings.
CAUTION
As with EDIT, LEARN changes will only be temporary
until saved in a Custom Program.
If LEARN has been used to develop a discriminate
program, the ACCEPT or REJECT V.D.I. numbers
can be reviewed by using the EDIT feature.
38
Chapter 5 DFX
™ Pro Options17. Recovery Speed
Speeds target responses, so several targets that are
close together can each respond.
When a metal is detected, it takes a fraction of a
second for the detector to process the signal before
it can respond to another metal target nearby. The
time it takes to process the fi rst metal target signal
so that the second metal target signal can respond
is called RECOVERY SPEED.
There are advantages and disadvantages to fast
(high numbers) and slow (low numbers) RECOVERY
SPEEDS. Faster RECOVERY SPEEDs work
well in high trash areas. However, they will have
some diffi culties with very deep targets as well
as double responses on shallow targets. Slower
RECOVERY SPEEDs do not work very well in
high trash areas. However, they will have better
responses on very deep targets. Slower speeds
also have more defi nitive discrimination sounds.
A custom setting needs to be found that suits the
preferences of the individual and the conditions in
the area. As a general rule, the closer together the
metal targets are in an area, the faster the recovery
speed should be. The more spacing between targets,
the slower the speed should be. Don't use the
fast speed if you don't need to.
Sweep speed (page 43) and more signifi cantly,
Ground Filtering adjustments (page 44) will also
dramatically improve or degrade performance in
high trash.
(Discrimination section)
Tips -
Use faster speeds(higher numbers) for trashy
areas, slower speeds (lower
numbers) for low trash
areas and/or improved discrimination.
Settings from 1
- 40 are available.
39
Chapter 5 DFX
™ Pro Options18. Bottlecap Reject
Adjusts how strongly the instrument rejects or
breaks up on iron.
Most starting programs use the minimum setting.
As larger numbers are selected, more
bias rejectionagainst iron occurs.
The advantage of higher BOTTLECAP REJECT
settings is that in high-trash areas more decisive
iron rejection occurs. Trash becomes easier to identify
by the broken sounds they produce.
The disadvantage of a high Bottlecap Rejection
setting is if an iron target is close to a good metal,
the high degree of
bias against iron may cause thedetector to cancel both responses. Another disadvantage
is that all targets, iron and non-iron, tend to
start sounding more broken at high levels of BOTTLECAP
REJECT. The operator needs to fi ne tune
BOTTLECAP REJECT according to their preferences
and the conditions being searched.
Some ground conditions make it diffi cult for the instrument
to recognize iron. BOTTLECAP REJECT
allows compensation for these areas.
(Discrimination section)
Tips -
If having diffi cultiesrecognizing the broken
sounds of iron, try increasing
BOTTLECAP REJECT.
Settings from 1 - 20 are
available.
40
Chapter 5 DFX
™ Pro Options19. Hot Rock Reject
(Discrimination section)
Tips -
Hot Rocks are oftendescribed or categorized
as either negative/magnetic
(cold rock) or positive/conductive
(hot rock). Typically
a negative or magnetic
“cold rock” will respond in
the search mode, however,
once the trigger is
squeezed for pinpointing it
ceases to respond. A positive
or conductive “hot rock”
will continue to respond
during pinpointing.
If hot rocks are a problem
in the area being searched,
in most cases a HOT
ROCK REJECT setting can
be found that will minimize
their target like responses
compared to real metal
target responses in the +95
category. Settings from
1 - 20 are available.
Hot rocks (rocks higher or different in mineralization
than the surrounding ground) respond as +95
on the V.D.I. scale. Unfortunately in some ground
conditions very deep, small, or unusual real metal
targets may also indicate +95. In the past an operator
would either accept +95 with the DISC EDIT
feature and hear hot rocks as a target response
“beep”, or reject +95 and not hear a target like response
from + 95 target types.
The HOT ROCK REJECT features allows a compromise
between total rejection or total acceptance
of the + 95 V.D.I. indication. Disc Edit Accept or
Reject of +95 will only control the visual displaying
of +95 with the Visual Discrimination feature ON.
To reject or accept +95 with the audio discrimination,
Audio DISC must be on, and the HOT ROCK
REJECT feature adjusted for your preference-regarding
+95.
A HOT ROCK REJECT range of 0 to 20 is provided.
At 0 the same characteristics can be expected
as EDIT ACCEPT +95 has provided with past
Whiteʼs models. At 20 the same characteristics can
be expected as EDIT REJECT +95 provided with
past Whiteʼs models.
At 10 a compromise between accepting +95 and
rejecting +95 is achieved. A hot rock may or may
not produce a target like response depending upon
many factors such as the actual size of the hot rock,
degree of difference between the hot rockʼs mineralization
and the surrounding ground, the current
ground balance setting, and the Sensitivity/Gain
settings.
Hot Rock Reject provides for 19 shades of gray between
totally accepting all hot rocks (0), and totally
rejecting all hot rocks (20).
41
20. Sweep Speed
(Discrimination section)
Tips -
Typically a competitionor speed hunt would
indisputably be a situation
when an operator would desire
the best performance
with a faster loop sweep
speed. Another area well
suited to faster loop sweep
speeds are large areas that
have few metal items near
each other.
Typically high trash areas,
or older areas that deserve
a slower more methodical
search, are ideal for
slower loop sweep speeds.
Settings from 1 - 20 are
available.
The quickness the loop or search coil is passed from
side to side is critical for modern metal detectors
to perform properly regarding detection depth and
discrimination. Sweep Speed is often a personal
preference feature. Individuals may like or dislike
a particular model based on itʼs required ideal
sweep speed. Additionally an individual may prefer
a quicker sweep speed for a particular area or type
of searching and a slower sweep speed for another
area or type of searching. Most metal detectorʼs
sweep speed is designed into the electrical circuit
and not adjustable.
The SWEEP SPEED of the DFX is adjustable in all
settings except a GROUND FILTER setting of 2.
A GROUND FILTER setting of 2 has a fi xed (not
adjustable) sweep speed.
An adjustment range from 1 to 20 is available. 1 is
the slowest ideal (best performing) loop or search
coil sweep speed, 20 is the quickest ideal (best performance)
sweep speed.
SWEEP SPEED regulates the ideal (best performance)
loop sweep speed by controlling the width
of the target signal the detectors electronic circuit
samples or analyzes. By expanding the sample window
(lower number settings) a slower loop sweep
speed becomes ideal. By narrowing the sample window
(higher number settings) a quicker loop sweep
speed becomes ideal.
RECOVERY SPEED is highly interactive with
SWEEP SPEED and GROUND FILTERING.
Generally faster RECOVERY SPEEDS are better
suited to faster SWEEP SPEEDS. Generally Slower
RECOVERY SPEEDS are better suited to slower
SWEEP SPEEDS. GROUND FILTERING adds
new dimensions to these features. SWEEP SPEED,
RECOVERY SPEED, and GROUND FILTERING
all have a dramatic effect on the way the discrimination
responds to both trash and valued metal
alloys.
Chapter 5 DFX
™ Pro Options42
21. Ground Filtering
(High Pass Filters or
Differentiators)
(Discrimination section)
Tips -
Metal detectors areoften described or categorized
by the amount
of electronic fi ltering used
to distinguish between the
ground, trash, and valued
metal alloys. Typically the
fewer the fi lters, the quicker
the metal detector can
respond between several
metals targets close to
each other. However, detection
depth in mineralized
ground quickly diminishes
with fewer fi lters. Audio
discrimination sounds are
not as pronounced with
reduced fi ltering. The more
the electronic fi lters the
better the detection depth
in mineralized ground and
audio discrimination becomes
more pronounced.
However, more fi lters
equals slower responses
and several targets near
each other become diffi
cult to sort out or respond
separately. Settings from 2
- 6 are available.
GROUND FILTERING is adjustable with the
DFX. The fi rst two primary fi lters are contained
within the hardware (electrical parts). The remaining
fi lters are contained within the computer software
allowing full user adjustment.
The DFX GROUND FILTERING has an adjustment
range from 2 through 6. At a setting of 2
SWEEP SPEED is not adjustable (fi xed).
Selection of 2 fi lters allows for the best performance
in high trash areas of medium to low ground
mineralization. Combined with the RECOVERY
SPEED, and BOTTLECAP REJECTION the DFX
will pull some good targets from previously heavy
hunted high trash areas.
Selection of 3 fi lters will allow for better depth
performance than 2 in slightly higher ground mineralization.
Selection of 4 fi lters allows for the traditional high
end Whiteʼs fi ltering ideal for medium to high mineralized
ground.
Selection of 5 or 6 fi lters allows for new levels of
fi ltering for extreme ground conditions. Although
some models have been described as having 6 fi lters
in the past, two of those six were dedicated to visual
indications alone. The DFX 6 fi lter selection dedicates
all six to ground rejection, discrimination,
and audio detection. For those who search extreme
mineralized ground conditions the DFX with its
multifrequency salt/conductive mineral cancelation
and new levels of ground fi ltration will provide for
performance levels never before available.
Chapter 5 DFX
™ Pro Options43
22. Visual Disc.
When ON, REJECTed V.D.I. numbers and their
associated ICONS are prevented from appearing
on the display. When OFF, all V.D.I. numbers and
associated ICONS appear.
VISUAL DISC. "ON" eliminates both the V.D.I.
number
and the ICON (NAIL, FOIL, PULL TAB,etc.) of
REJECTed V.D.I. numbers from appearingon the display. In other words if Visual Discrimination
is ON, and a specifi c target is rejected (for
example 0-IRON) then 0-IRON will not appear on
the display. If VISUAL DISC. is OFF, all the display
indications will appear regardless of whether
the specifi c V.D.I. number is ACCEPTed or REJECTed.
Visual Discrimination is based on the current discriminate
program.
Visual Discrimination has the advantage of eliminating
a large number of
REJECTed V.D.I. numbersfrom appearing on the display. The disadvantage
is that much of the visual display information
will not appear for you to interpret questionable
target responses.
(Display section)
Tips -
Typically you're notinterested in the REJECTed
target information. Eliminating
it from appearing
reduces or cleans up the
display information you
must interpret. ON is recommended
for most search
conditions.
23. Icons
Graphic representation of metal targets, "NAIL,
FOIL, PULL TAB, SCREW CAP, COINS".
ICONS are designed for average use inside the
USA. If searching in other countries, or in areas
where such common types of targets are not expected,
ICONS may be distracting. In such cases,
this option allows the ICONS to be turned off.
Tips -
The ICONS providea quick way of reading the
display information. ON is
recommended. If you do not
use these ICONS, selecting
OFF will speed the remaining
display indications.
Chapter 5 DFX
™ Pro Options44
24. V.D.I. Sensitivity
Controls how strong a target must respond to produce
a display indication, and controls a third digit
(fraction) of the V.D.I. number.
V.D.I. Sensitivity controls the intensity (strength)
of the target signal needed to activate the display
indications. A low V.D.I. Sensitivity setting would
require a strong target signal to trigger the display
indications. A higher V.D.I. Sensitivity setting
would require very little target signal to trigger the
display indications.
To provide greater specifi c target resolution, levels
of 86 and above will provide a third V.D.I. digit
(.0) to better evaluate targets. During EDIT only
the fi rst two digits can be programmed ACCEPT or
REJECT.
As with all sensitivity levels, if set too high for
the area, the detector will become unstable and the
display indications unreliable.
Low ground mineralization is typically a good
indication that high V.D.I. sensitivity settings are
appropriate. Heavy mineralization or electrical
interference are conditions where a lower V.D.I.
Sensitivity setting is appropriate.
This feature is designed to allow adjustment of the
display stability. However, because the instrument's
display and audio tone are closely associated in
many of the audio modes, the V.D.I. Sensitivity
may increase or decrease overall audio sensitivity.
(Display section)
Tips -
Lower V.D.I. SENSITIVITYlevel (smaller
numbers) offer fewer and
more reliable display indications.
However, some
deep targets may or may
not respond with a display
indication. Higher V.D.I.
SENSITIVITY levels (higher
numbers) produce more
display indications, but less
reliability. Levels of 86 and
above produce a third V.D.I.
digit (.0), providing greater
resolution. Settings from 0
- 99 are available.
Third number (.8)
Chapter 5 DFX
™ Pro Options45
25. D.C. Phase
Measurement of the ground mineralization, or
measuring the phase (V.D.I. reference number) of a
specifi c metal target during pinpointing.
When D.C. PHASE is ON, and the TRIGGER
squeezed and released, normal searching begins.
When a target is located, or when the operator
wants to measure a target or the ground, the TRIGGER
is squeezed and held as if to pinpoint. When
the loop is held stationary over the target or ground,
the D.C. PHASE is shown on the upper-right side of
the display. The depth reading can be used to help
center the loop over a target for more accurate indications.
The audio tone will also assist in centering
the loop over the target.
Metal targets in the ground will produce a measurement
which represents the target indication ± the
ground measurement. To measure the target alone,
move the loop off to one side (being sure to hold
the loop directly on top of the ground mineral),
and release and re-squeeze the trigger. Then move
the loop back over the target. This should allow a
proper D.C. PHASE reading for the target alone.
The relationship between D.C. PHASE, Ground
Balance, V.D.I. number and Discrimination is complex.
Results are not always repeatable in varied
ground conditions. Ground and target responses can
distort the detection fi eld of the loop in a number
of ways, by bending, refl ecting, absorbing and thus
altering the phase and amplitude the detector measures.
This in turn produces inconsistencies in the
relationships of these features.
When considering specifi c numbers it is important
to know D.C. phase is provided by the 15 kHz
channel without normalization. The V.D.I. scale
is distorted/expanded in the lower end of the scale
(foil/nickel) and compressed in te higher end of the
scale (copper/silver).
(Display section)
Tips
- In specifi c groundconditions, certain Basic
Adjustments and Pro Options
may produce better
performance. By measuring
the ground and taking
notes, such conditions may
also be recognized in other
areas and dealt with by using
similar settings.
The D.C. Phase of the ground has a relationship
to the proper Ground Balance setting. This is of
particular interest to those who use the optional
COARSE or FINE G.E.B. (Manual Ground Balance).
Manual Ground Balance has a range that
covers V.D.I. numbers from -95 - +10. A Manual
Ground Balance Coarse setting of 0 equals a
D.C. PHASE of negative -95. A Coarse setting of
255 equals a D.C. Phase of +10. As mentioned
under COARSE and FINE G.E.B., Ground Balance
is not the same as EDITing these V.D.I.
numbers for REJECT. However, if your ground
measures -90, ACCEPTing
V.D.I. -90 will produce operational problems as
the detector will see the ground as a target. With
the same logic, if a target measures -90, and the
ground measures -90, and the detector is Ground
Balanced to this -90 ground, such a target will be
virtually invisible to the detector. These conditions
would be extremely rare however; the point is
there must be a difference between the target and
the ground for the target to be detected.
Chapter 5 DFX
™ Pro Options46
(Display section)
26. Accumulate
ON combines SignaGraph
® information over multipleloop passes, OFF shows SignaGraph
® informationonly from the last sweep of the loop.
Accumulate allows the SignaGraph
® to continuallycollect information. This collecting of information
continues from one sweep of the loop to the next.
Eventually, if only ACCUMULATE is selected,
the SignaGraph
® will completely fi ll, requiring thatthe TRIGGER be squeezed and released to clear it
so that further information may be viewed. FADE
is suggested to be used in combination with ACCUMULATE
so that noncurrent information gradually
disappears and excessive TRIGGERing is not
required. FADE will gradually reset or clear the
SignaGraph
® to eliminate old information.Tips -
ON is suggested,since it takes several
sweeps of information to
recognize trends.
27. Average
Emphasizes the most common or predominate SignaGraph
®
indications.AVERAGE
does not necessarily allow showing ofall the available information on the SignaGraph
®. Itaverages
the information received, and shows thisaverage on the SignaGraph
®. When used in combinationwith ACCUMULATE it has more information
to average, which results in more accurate
indications of trends. FADE is suggested to clear
the display of old information, rather than excessive
TRIGGERing.
Tips -
Most benefi cialwhen used in combination
with ACCUMULATE. AVERAGE
ON is suggested
as it reduces indications
uncharacteristic of a particular
target, which may
occur due to loop angle
or target positioning in the
ground.
If ACCUMULATE is OFF, and AVERAGE
is OFF, then SINGLE SWEEP is active.
SINGLE SWEEP displays SignaGraph
®information received during the current sweep
of the loop, no more and no less. The next
sweep of the loop will clear all information
from the SignaGraph
® and list the informationreceived only within that sweep. Fade is not
needed in the SINGLE SWEEP mode as each
pass of the loop will clear the display and provide
current information automatically. Several
SignaGraph
® indication samples occurduring each sweep of the loop. It is therefore
normal to see one or more SignaGraph
® bars,even in the SINGLE SWEEP mode.
Chapter 5 DFX
™ Pro Options47
(Display section)
28. Fade
Clears or fades noncurrent SignaGraph
® information(bars).
FADE allows past information to automatically
clear or fade from the SignaGraph
®. Without Fade,or with too slow of a FADE rate, the SignaGraph
®will fi ll with information that is no longer valid as
you sweep through a search area.
A minimum setting of 1 equals the least degree of
fading. A maximum setting of 14 selects a very
quick fade rate. The SignaGraph
® information willautomatically clear from the graph quickly. Ideally,
a Fade Rate should be selected that allows time to
adequately view the SignaGraph
® information yetstill clear the graph in a timely manner.
Tips -
Recommendedfor all but the SINGLE
SWEEP mode. Adjust
the rate of FADEing to
have time to view the
SignGraph™ prior to it
resetting. However, do
not set it so slow as to
show noncurrent information.
Settings from 1
- 14 are available.
Chapter 5 DFX
™ Pro Options48
(Preamp Gain section)
29. Preamp Gain
Selects the intensity of the signal received from the
loop.
PREAMP GAIN (called
Signal Balance on somemodels) is used to promote stability and performance.
Like a sensitivity control, too much PREAMP
GAIN will result in unstable operation and
unreliable indications.
Unlike a sensitivity control,PREAMP GAIN will have a substantial effect on
OVERLOAD.
For maximum detection depth, fi ne tune the PREAMP
GAIN to the highest number setting without
causing OVERLOAD, and/or unstable operation.
More adjustment levels (range) are available than
what may be usable. You may never encounter
an area where maximum PREAMP GAIN can be
used. Electrical interference may make it diffi cult
to receive an Air Balance at high PREAMP GAIN
settings.
Selections such as MIXED MODE or AUDIO
DISC OFF may not allow as high a PREAMP
GAIN level as other selections. This is normal as
some of these modes naturally see more targets and
ground, and they may still provide superior performance
and depth even with the lower PREAMP
GAIN selection.
Every time the PREAMP GAIN level is changed,
the detector should be re-ground balanced. Once
in an operating mode, simply press ENTER to reground
balance.
Tips -
Higher levelsincrease detection depth.
However, the detector
must be stable to be able
to recognize a target.
OVERLOAD should not
appear on the display
when only ground minerals
are present. Settings
from 1 - 4 are available.
Chapter 5 DFX
™ Pro Options49
(Multi Frequency Method section)
30. 2 Frequency (Best Data)
Transmits and processes data continuously at both
3 kHz and 15 kHz frequencies (salt eliminated).
Automatically chooses to use only the data from the
most reliable frequency (based on both magnitude
and phase) for each specifi c target.
Gold, nickel, and other lower conductive metals respond
more reliably at higher frequencies. Copper,
silver, and other higher conducting alloys respond
more reliably at lower frequencies. 2 Frequency
(Best Data) uses the multi frequencymode to cancel
ground and salt and then selects the most ideal
frequency for that particular target alloy on a target
by target basis.
31. 2 Frequency (Correlate)
Transmits and processes data continuously at both
3 kHz and 15 kHz (salt eliminated). Compares
data at 3 kHz and 15 kHz. Target signals that do
not provide reasonably predictable information at
both 3 kHz and 15 kHz are automatically rejected.
Iron typically doesnʼt compare predictably between
frequencies and thus improved iron rejection can be
expected with the use of Correlate.
Differences in the target signal at 3 kHz and 15 kHz
are predictable regarding valued metal alloys such
as gold, copper silver, etc.. If the two signals do
not match within a reasonable range of predictability,
most likely the target is not a valued metal and
therefore is rejected.
Multi Frequency Method
Only one of the four available multifrequency
methods, BEST DATA, CORRELATE, 1 kHz,
and 15 kHz, can be "ON" at any one given
time. For example if BEST DATA is "ON",
the remaining three multifrequency options
are automatically "OFF". To turn BEST DATA
"OFF", requires the selection of one of the three
remaining methods. In other words, an operator
never turns "OFF" a multifrequency method,
they simply select the desired method and turn
it "ON", all other methods are automatically
turned "OFF."
The MULTI FREQUENCY selection in use
appears continuously on the bottom of the LCD
display during searching. The ideal multi frequency
or single frequency setting will depend
on many different factors such as the amount,
degree, and type, of ground mineralization, the
types of metal alloys most desired, as well as
personal preferences. No one setting will be ideal
for all situations. A user should fi rst trust the
factory preset settings for the general types of
searching and then experiment to fi nd the most
ideal settings for that particular area and type
of search. Generally multi frequency settings
are better suited to areas that have both magnetic
(iron) and conductive (salt) components.
Inland areas may vary in this regard with the
soils moisture content. For example dry soil may
present mostly iron type characteristics possibly
making one of the single frequency modes a
better choice. The same area when the soil is wet
may exhibit conditions similar to a combination
of both iron and salt due to nonferrous metallic
type mineralizationʼs greater electrical activity
when wet. For example soils containing silver,
copper, or nickel oxides/nitrates react differently
in conditions from wet to dry. These soil traits
can occur naturally and are typical of areas with
mineral springs or volcanic origins. However,
be particularly aware of this wet/dry phenomena
in farming areas where the soil mineralization is
likely altered for agricultural purposes.
Chapter 5 DFX
™ Pro Options50
V.D.I. Normalization - Used in the 1 frequency
operating modes to correct the skewing of the traditional
(6.59 kHz) V.D.I. number display calibration.
2 Frequency modes require Normalization and thus
it is automatically ON in both the 2 Frequency (Best
Data) and 2 Frequency (CORRELATE) operating
modes. It is not an option in 2 Frequency modes.
When operating in the 1 Frequency (3 kHz) mode
Normalization ON recalculates the V.D.I. display
information to represent traditional V.D.I. display
calibration at Whiteʼs traditional frequency 6.59
kHz.
When OFF in the 1 Frequency (3 kHz) mode the
V.D.I. scale is distorted/expanded in the higher end
of the scale (copper/silver) and compressed in the
lower end of the scale (foil/nickel). This distortion
can be used to provide higher display or discrimination
resolution in this copper/silver coin area of the
scale. DISC EDIT will have to be confi gured to take
advantage of this expanded resolution.
When operating in the 1 Frequency (15 kHz) mode
Normalization ON recalculates the V.D.I. display
information to represent traditional V.D.I. display
calibration at Whiteʼs traditional frequency 6.59
kHz.
When OFF in the 1 Frequency (15 kHz) mode the
V.D.I. scale is distorted/expanded in the lower end
of the scale (foil/nickel) and compressed in the
higher end of the scale (copper/silver). This distortion
can be used to provide higher display or discrimination
resolution in this foil/nickel area of the
scale. DISC EDIT will have to be confi gured to take
advantage of this expanded resolution. The advan-
32. V.D.I. Normalization
33. 1 Frequency (3 kHz)
1 Frequency (3 kHz) - Operates at 3 kHz exclusively.
Provides for superior high iron mineral rejection
and depth when salt is not present. Also provides
for better depth on higher conducting metals such as
copper and silver alloys.
1 Frequency (3 kHz) provides an alternate search
mode when iron (without the presence of salt) is
extreme and the primary target is higher conducting
metals such as copper or silver. Some of Whiteʼs
early 1970 models operated at 3 kHz and are still
revered for there performance in high iron black
sands.
1 Frequency (15 kHz) - Operates at l5 kHz exclusively.
Provides for superior performance in medium
to low mineralization (without the presence of
salt) and/or when lower conducting gold and nickel
range targets are the primary targets.
1 Frequency (15 kHz) provides an alternative
search mode when the ground minerals are not
severe (without the presence of salt) and/or when
34. 1 Frequency (15 kHz)
(Multi Frequency Method section)
Normalization OFF chart for 3 kHz expands the high (copper/silver) end of the scale and compresses
the low (foil/nickel) end of the scale. In the 15 kHz mode the opposite occurs.
The high end compresses and the low end expands.
Chapter 5 DFX
™ Pro Options51
Factory Pre-Loaded Custom
EEPROM Programs
Whiteʼs has pre-loaded each of the four custom
EEPROM Program positions for you. These programs
can be erased simply by developing your
own program, starting with any of the nine available
programs, and using the SAVE or NAME feature
(pages 16-17).
The fi rst fi ve Factory Preset Programs are burnt
into permanent memory EPROM (Electronic,
Program-mable, Read, Only, Memory). Although
you can make changes to these programs while in
use, and you can modify and copy/save them to the
EEPROM positions for future use through battery
changes, the Factory Preset Programs will always
revert to their original factory settings. Only the
programs saved in one of the four available EEPROM
positions will save through battery changes.
Short term memory recall (ON and squeeze and
release the trigger) will maintain changes to a factory
program if a good battery remains in the unit.
To assure you retain special settings it is advised to
Save or Name them in one of the EEPROM positions.
Once you modify and Save/Name a factory
program to one of the EEPROM positions it is no
longer a Factory Preset Program and thus will save
for future use.
EEPROM stands for a special type of electronic
memory chip (Electrical, Erasable, Programmable,
Read, Only, Memory). This memory chip allows the
user to store up to four of their own programs for
future use through battery changes and storage.
To use a custom EEPROM Program Simply;
1. Turn the detector ON and wait for the
Main Menu.
2. Press ENTER to enter the Preset programs.
3. Use ARROW DOWN to scroll down the
Preset Program pages/screens until you see
thecursor beside the EEPROM program
you desire.
4. Press ENTER.
5. Press ENTER again to LOAD the program.
6. Air/Ground Balance and your ready to search
using the program stored in that position.
To store the current settings you are using do the
same thing only instead of LOAD, select SAVE or
NAME. LOAD it when you want to use those settings
again. Save or Name if you want to save the
DFXʼs current settings.
The idea is that once you have determined your
preferences for the particular features and settings,
you can store that entire program in one of the EEPROM
positions and have it ready for use whenever
you desire, without having to go through all the
options. Save your settings for future turn on and go
use.
Chapter 5 DFX
™ Pro Options52
Pre-Loaded EEPROM Programs
EEPROM DP-SILVER (Deep Silver)
A good general purpose program where the
majority of the trash is iron and small/
medium foil and the majority of the ex
pected targets are coins.
Popular performance modifi cations include:
Turning ON V.C.O..
Ground Filtering adjustment 2 for lower
minerals 3 medium minerals.
AutoTrac Offset +2.
Remember...if consistently digging a
particular trash target, simply make note
of the typical V.D.I. reference numbers,
go to Disc Edit and change those specifi c
V.D.I. numbers for rejection. Re-save
any changes if future use is desired.
EEPROM HI-TRASH
Provides a primarily coin program targeted more
toward trashy public areas. Rejects common
aluminum at the sacrifi cing of some jewelry.
Jewelry 18 K and above in the medium size
category is not likely to respond. However, areas
of common abundant aluminum trash can be
searched with good coin results as well as 14K
jewelry in the medium to small category. The
only way to get all the jewelry is to dig all the
aluminum, lead, and brass, which can be tedious
to the point of frustration in trashy areas.
Popular Performance modifi cations include:
Tone I.D. ON
V.C.O. ON
Ground Filtering 2 for lower mineral areas,
4 for more mineralized areas.
Auto Track Offset +2
Visual Disc ON
D.C. Phase ON
Re-save any changes if future use
is desired.
AC Sensitivity 65
1 Frequency (3 kHz)
Re-save any changes if future use
is desired.
EEPROM DEMO
Primarily a showroom or bench program for
testing or demonstrating, likely the fi rst
EEPROM slot an individual would choose to
save their own program in place of.
EEPROM HI-PRO
A high performance general purpose program not
for the meek at heart. Advanced features TONE
I.D., V.C.O., wide open DISC EDIT acceptance
of all nonferrous (valued alloy) targets, and high
Sensitivity/Gain, make this program really sing
for those who can handle the various audio
pitches and depth of information. If you like
silent search, this isnʼt the program for you
Sensitivities and Gains may need to be reduced
in areas of heavy electrical interference.
Popular Performance modifi cations include;
Mixed Mode ON
Tone I.D. OFF
Autotrac Offset +5
Ground Filtering 2 for lower
mineralization, 4 for higher
mineralization.